A Laser Particle Size Analyzer — Bettersizer 2600

The Bettersizer 2600 utilizes widely recognized Laser Diffraction Technology for particle measurement, with a range of particle sizes from 0.02 to 2,600 μm. To transform light signals from the scattering spectrum into electrical signals that are sent into intelligent software, there are 92 photoelectric detectors. A precise and reliable particle size distribution can be obtained by applying the Mie scattering theory to the data and carrying out mathematical conversion.

The Bettersizer 2600's modular design gives it a range of useful features. Particle size and shape analysis are provided by the dynamic imaging module, which also allows combined laser and imaging tests with a measurement range expansion to 3,500 μm. The different dispersion system modules support an extensive array of testing requirements, including dry and wet dispersion methods, to satisfy different testing requirements.

Ask an Expert! Introducing Bettersizer 2600

Video Credit: Bettersize Instruments Ltd.

Features and benefits

  • Measurement: Particle shape and size
  • A broad range of particle sizes: dynamic image: 2.0–3,500 μm; wet dispersion: 0.02–2,600 μm; dry dispersion: 0.1–2,600 μm
  • Dual optical system: Laser Diffraction and Dynamic Imaging
  • High-Tech Laser Diffraction System: Integrating Fourier and inverse Fourier designs
  • 92 distributed spherical detector arrays: light signals between 0.016° and 165° are detected
  • Auto-alignment of the laser diffraction system eliminates manual adjustments
  • Modular dual-camera imaging system with 24 detailed particle parameters
  • Dispersion units can be switched seamlessly between dry and wet methods
  • User-friendly software is efficient and simple to use
  • Compliance with ISO 13320, 21 CFR Part 11, USP <429>, ISO 13322-2

Dynamic Imaging Module: PIC-1.

Dynamic Imaging Module: PIC-1. Image Credit: Bettersize Instruments Ltd.

The PIC-1 dynamic imaging module is a broad and adaptable dynamic image analysis instrument designed to work seamlessly with the Bettersizer 2600 laser particle size analyzer and wet dispersion systems.

Parameter & Specification

  • Magnification: 0.5× and 10×
  • Imaging rate: 120 fps
  • Illumination: White and blue LED
  • Image recognition: Up to 10,000 particles per minute
  • Particle size range: 2–3,500 μm
  • Size and shape parameters: 24
  • Camera type: CCD sensor, 1.5 Megapixels

Source: Bettersize Instruments Ltd.

Sample Dispersion Modules BT-802 BT - 804 BT-80N BT - 80N Pro BT-902 BT-903
Sample Dispersion Wet sample dispersion Wet small volume sample dispersion Anti-corrosive sample dispersion Anti-corrosive Wet sample dispersion Dry sample dispersion Dry small volume sample dispersion
Dispersion Modules
Combine with Main Device
Volume / Sample Mass 600 mL 8 mL 50 - 80 mL (dispersion medium) 80 - 200 mL (dispersion medium) 0.2 g-10 g 0.05 g-1 g
Automation Fully automated Semi-automated Semi-automated Fully automated Fully automated Fully automated

 

Intuitive and powerful software

  • Simply clicking a button will convert the dispersion from wet to dry
  • Editable reports and automatic data backup
  • Based on sample size and type, accurate analysis is accomplished through the appropriate application of the Fraunhofer or Mie evaluation models
  • Simple operation and an easy-to-understand interface
  • Easy-to-use SOP operation
  • Automatic cleaning routine
  • Real-time mode to determine optimal measurement parameters
  • Fully automated measurement process with self-adjusting calibration

Applications

The following domains are among those where the instrument is used:

  • Cosmetics
  • Food and Beverage
  • Mining and Materials
  • Paints, Inks, and Coatings
  • Pharmaceuticals
  • 3D Printing Materials
  • Abrasives
  • Batteries
  • Building Materials
  • Ceramics

A Laser Particle Size Analyzer — Bettersizer 2600

Image Credit: Bettersize Instruments Ltd.

Other Equipment by this Supplier

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.