Series 1000 UV/Visible Spectrophotometers from Cecil Instruments

High Quality Low Cost

When cost is a primary consideration of selection, the Series 1000 provides low cost, high specification, quality instruments for both the UV and visible ranges.

The designs offer an ideal combination of performance, quality and reliability for educational use; as is witnessed by the large number of Universities, Polytechnics and Colleges who are multiple users of the range.

Ease of Operation

With only six, carefully programmed operating keys, the Series 1000 spectrophotometers are exceptionally easy to use. Up-down keys, with automatic slew rate acceleration, make wavelength selection, to 0.1nm, convenient and rapid. Absorbance, Transmittance or Concentration may be measured; the latter using standards or by entering a factor.

Wavelength Precision

Very precise wavelength selection, with readout to 0.1nm, provide the high degree of reproducibility needed for accuracy, particularly when measuring on a sloping background.

Convenient Operation

Design advantages of the series 1000 instruments include self test and calibration at switch on, automatic lamp and filter selection coupled to wavelength and high overall stability eliminating frequent resetting of the Absorbance zero when making extended measurements.

Deuterium Lamp Save

UV-visible instruments allow the Deuterium lamp to be switched off when working in the visible region, to extend lamp life. Switch on is automatic if a UV wavelength is selected. Deuterium Lamps are guaranteed for one year.

User Benefits

  • Easy Use
  • Simple Kinetics
  • Low Cost     
  • Deuterium Lamp Save
  • Self Test and Calibration  
  • Auto Lamp and Filter Selection                     
  • One year UV Lamp Guarantee

Peak Seek

The measurement of an absorption band should always be carried out at the wavelength of peak absorption to obtain results of the highest accuracy and reproducibility.

An automatic peak seek facility is provided. To enhance discrimination and accuracy automatic compensation of the reference energy background - baseline flattening - is carried out, followed by precise peak location. The instrument is set to the peak wavelength, ready for use.

Sample Temperature Control

Temperature control by water circulation is possible with the Series 1000 for a single cell, SIP flowcell, or for 4 cells mounted on the cell changer. A special sample compartment lid and pipe port are provided for use with water temperature control.

Convenient Sampling

The large and accessible sample compartment accommodates a wide range of sample holders in addition to the standard single cell holder. These include a 4 cell changer, water thermostatted cell holders and a SIP sampling system which fits within the sample compartment.

SIP Flowcell Sampling

Used with Series 1000 instruments the SIP sampling accessory allows samples to be measured without the inconvenience of cell handling, or danger of cell breakage. Samples are drawn into the cell by depressing the sample key on the control panel, to displace the previous sample.

The pump unit is mounted within the cell compartment. Cells of up to 40 mm pathlength are available and samples as small as 300 µl may be measured in a 10 mm pathlength cell.

Sampling

  • Cell Temperature Control
  • 100 mm Cell Holders
  • 50 µl Cell Holder
  • Film or Filter Holder

Specifications

Optical System

Littrow monochromator using 1200 L/mm holographic grating; coated optics.

Optical Bandwidth

8 nm

Wavelength Selection

Keyboard controlled by up-down keys

Wavelength Range

200-1100 nm CE 1021

Wavelength Accuracy

325-1100 nm CE 1011

Wavelength Precision

Within 1 nm

Wavelength Display

0.1 nm

Photometric Ranges

Large seven segment bright LED's

Photometric Accuracy

-0.3 to 3.0 A, 0-200%T, 0-9999C

Photometric Noise

1% or 0.005 A whichever is greater

Straylight

Less than ±0.0002 A

Absorbance Zero Stability

Less than 0.05% at 220 nm and 340 nm

Absorbance Zero Setting

Better than ±0.001 A/Hr.

Peak Seek

0 A and 100%T automatic by press button

Filter and Lamp Selection

Automatic with baseline flattening

Self Test and Calibration

Automatic - coupled to wavelength

Computer Interface

Automatic at switch on

Sample Compartment Dimensions

Bi-directional serial RS232c

Size

196 x 96 x 107 mm

Power Requirement

480 x 340 x 205 mm

Weight

110-250 V, 50/60 Hz, 120 W

Other Equipment by this Supplier

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.