High Quality Low Cost
When cost is a primary consideration of selection, the Series 1000 provides low cost, high specification, quality instruments for both the UV and visible ranges.
The designs offer an ideal combination of performance, quality and reliability for educational use; as is witnessed by the large number of Universities, Polytechnics and Colleges who are multiple users of the range.
Ease of Operation
With only six, carefully programmed operating keys, the Series 1000 spectrophotometers are exceptionally easy to use. Up-down keys, with automatic slew rate acceleration, make wavelength selection, to 0.1nm, convenient and rapid. Absorbance, Transmittance or Concentration may be measured; the latter using standards or by entering a factor.
Wavelength Precision
Very precise wavelength selection, with readout to 0.1nm, provide the high degree of reproducibility needed for accuracy, particularly when measuring on a sloping background.
Convenient Operation
Design advantages of the series 1000 instruments include self test and calibration at switch on, automatic lamp and filter selection coupled to wavelength and high overall stability eliminating frequent resetting of the Absorbance zero when making extended measurements.
Deuterium Lamp Save
UV-visible instruments allow the Deuterium lamp to be switched off when working in the visible region, to extend lamp life. Switch on is automatic if a UV wavelength is selected. Deuterium Lamps are guaranteed for one year.
User Benefits
- Easy Use
- Simple Kinetics
- Low Cost
- Deuterium Lamp Save
- Self Test and Calibration
- Auto Lamp and Filter Selection
- One year UV Lamp Guarantee
Peak Seek
The measurement of an absorption band should always be carried out at the wavelength of peak absorption to obtain results of the highest accuracy and reproducibility.
An automatic peak seek facility is provided. To enhance discrimination and accuracy automatic compensation of the reference energy background - baseline flattening - is carried out, followed by precise peak location. The instrument is set to the peak wavelength, ready for use.
Sample Temperature Control
Temperature control by water circulation is possible with the Series 1000 for a single cell, SIP flowcell, or for 4 cells mounted on the cell changer. A special sample compartment lid and pipe port are provided for use with water temperature control.
Convenient Sampling
The large and accessible sample compartment accommodates a wide range of sample holders in addition to the standard single cell holder. These include a 4 cell changer, water thermostatted cell holders and a SIP sampling system which fits within the sample compartment.
SIP Flowcell Sampling
Used with Series 1000 instruments the SIP sampling accessory allows samples to be measured without the inconvenience of cell handling, or danger of cell breakage. Samples are drawn into the cell by depressing the sample key on the control panel, to displace the previous sample.
The pump unit is mounted within the cell compartment. Cells of up to 40 mm pathlength are available and samples as small as 300 µl may be measured in a 10 mm pathlength cell.
Sampling
- Cell Temperature Control
- 100 mm Cell Holders
- 50 µl Cell Holder
- Film or Filter Holder
Specifications
Optical System
|
Littrow monochromator using 1200 L/mm holographic grating; coated optics.
|
Optical Bandwidth
|
8 nm
|
Wavelength Selection
|
Keyboard controlled by up-down keys
|
Wavelength Range
|
200-1100 nm CE 1021
|
Wavelength Accuracy
|
325-1100 nm CE 1011
|
Wavelength Precision
|
Within 1 nm
|
Wavelength Display
|
0.1 nm
|
Photometric Ranges
|
Large seven segment bright LED's
|
Photometric Accuracy
|
-0.3 to 3.0 A, 0-200%T, 0-9999C
|
Photometric Noise
|
1% or 0.005 A whichever is greater
|
Straylight
|
Less than ±0.0002 A
|
Absorbance Zero Stability
|
Less than 0.05% at 220 nm and 340 nm
|
Absorbance Zero Setting
|
Better than ±0.001 A/Hr.
|
Peak Seek
|
0 A and 100%T automatic by press button
|
Filter and Lamp Selection
|
Automatic with baseline flattening
|
Self Test and Calibration
|
Automatic - coupled to wavelength
|
Computer Interface
|
Automatic at switch on
|
Sample Compartment Dimensions
|
Bi-directional serial RS232c
|
Size
|
196 x 96 x 107 mm
|
Power Requirement
|
480 x 340 x 205 mm
|
Weight
|
110-250 V, 50/60 Hz, 120 W
|