Flame 100 - Sets New Standards in the Bunsen Burner Class!
The safe alternative for all traditional Bunsen or alcohol burners!
- Flame without match
- Innovative safety technologie
- Simple handling
- Cost-saving and environmentally friendly
Multi-Use
The Flame 100 is ideally suited for all flame related applications in the laboratory. The 15 millimeter precision flame allows graduated heating of dental tools as well as safe sterilization of microbiological instruments. Flame size and intensity can be adjusted infinitely.
Easy Operation
The safety Bunsen burner Flame 100 activates immediately with the push of a button. No match or a pilot flame are required. Optionally, the Flame 100 can also be operated by a foot pedal or an external infrared motion sensor. The Flame 100 is suitable for stationary natural gas and propane/butane gas supplies as well as gas cartridges or gas cylinders. Numerous adapter systems are optionally available.
Reliable Safety
The proven Safety Control System (SCS) is also incorporated in the Flame 100. All potential hazards are constantly monitored and, if necessary, protective measures – such as the shutting off the gas supply – are activated. In addition to the ignition and flame control function and the overheating protection the safety package also features the continuous burner head control BHC. BHC unfailingly identifies burner head clogging by liquids or solid substances. Compared with a conventional Bunsen burner, the Flame 100 with the safety standard „SCS“ eliminates the risk of a gas leak or an explosion.
Efficient
The Flame 100 is economical to operate and attractively priced for any laboratory, thus making savings for both your budget and the environment. Compared with traditional Bunsen burners, the gas consumption is reduced to a minimum, because the flame burns only when it is really needed!
Compact and Rugged
The housing and burner tube are made of stainless steel. The removable burner tube makes cleaning easy and the small foot print is an advantage for any lab bench.
Technical Data
Technology |
Microprocessor |
Programs |
|
Button: |
Start-Stop with timer, 60 min |
Foot pedal: |
Standard (flame during pressed foot pedal, foot pedal optional) |
Safety features |
|
Safety Control System (SCS) with gas safety cut off: |
ignition and flame control
temperature monitor
burner head clogging monitor (BHC)
automatic unit switch off, 4h |
Gas supply and consumption |
|
Gas connection: |
1/4” left with gas filter |
Gas types: |
II2ELL3B/P: natural gas E/LL,18 - 25 mbar liquid gas, 47,5 - 57,5 mbar |
Connected load: |
43 g/h liquid gas, 49 l/h natural gas (LL) |
Continuous cartridge operation: |
CV 360 - 65 min
CG 1750 - 210 min
C 206 - 230 min
CP 250 - 305 min
CV 470 - 550 min
CV 270 - 280 min |
Temperatures |
|
Flame temperature: |
1200 °C on liquid gas
1170 °C on natural gas (E) |
Temperature threshold level: |
0.66 kW liquid gas, 10.66 kW natural gas |
Electrical |
|
Power consumption: |
2 VA (stand by max. 0.1 VA) |
Power connection: |
100-240 V / 50/60 Hz / max. 0.3 A; 9 V DC / 1.3 A
Level 6 (stand by power consumption max. 0.1 W) |
Mechanical |
|
Burner tube: |
removable, stainless steel |
Measurements (w x h x d): |
89 x 34 x 88 mm |
Height with burner tube: |
94 mm |
Weight: |
385 g |
Licenses |
|
DIN-DVGW Reg.-No.: |
NG-2211AS0167 |
CE: |
EN 61326-1, EN61010-1, EN61010-2-010 |
EU guidelines: |
2014/30/EU, 2014/35/EU, 2011/65/EU |
Flame 100