Ion levels poor indicator for hip arthroplasty debris

By Lynda Williams, Senior MedWire Reporter

Research shows that plasma metal ion analysis is only moderately effective at identifying patients with adverse reaction to metal debris (ARMD) following metal-on-metal (MoM) hip arthroplasty.

Metal artifact reduction sequence-magnetic resonance imaging (MARS-MRI) screening detected ARMD in 40% of 209 patients with unilateral symptomatic MoM hip arthroplasties an average of 1.9 years after surgery.

Analysis showed that patients with MARS-MRI ARMD had significantly higher levels of both chromium (5.9 vs 4.3 µg/L) and cobalt (8.5 vs 3.5 µg/L) than those without the condition. There was a significant and positive correlation between levels of the two ions.

But compared with MARS-MRI results, a plasma cobalt or chromium level above 7 µg/L was just 65% specific and 57% sensitive for identifying ARMD, with positive and negative prediction values of 52% and 69%, respectively, report I Malek (Wales Deanery, Cardiff, UK) and co-authors

When the threshold for ARMD was reduced to a cobalt or chromium level of 3.5 µg/L or above, the sensitivity increased to 86% but specificity fell to just 27%. While a 2.0 µg/L threshold for either ion would give 90% sensitivity, specificity at this threshold would fall to 25% for cobalt and 14% for chromium.

"Plasma levels of cobalt and chromium cannot therefore be used as a sole screening test for the presence of ARMD and should be used in combination with symptoms, plain radiological findings and cross sectional imaging," the researchers write in the British edition of the Journal of Bone and Joint Surgery.

Recommending that clinicians have a low threshold for use of cross-sectional imaging in patients with MoM hip arthroplasty, even in the absence of high plasma ion levels, they conclude: "We welcome the updated [Medicines and Healthcare products Regulatory Agency] guidance that recommends MARS-MRI or ultrasound in all symptomatic patients with a MoM arthroplasty."

Licensed from medwireNews with permission from Springer Healthcare Ltd. ©Springer Healthcare Ltd. All rights reserved. Neither of these parties endorse or recommend any commercial products, services, or equipment.

Comments

The opinions expressed here are the views of the writer and do not necessarily reflect the views and opinions of News Medical.
Post a new comment
Post

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.

You might also like...
The potential to optimize laboratory testing and operations with automation and AI