Clinical study shows efficacy, safety of novel drug-eluting stent with improved radiographic visibility

This first randomized clinical study of a polymer-coated zotarolimus-eluting stent (Resolute Onyx) that utilizes a novel thin-strutted metallic platform allowing for better x-ray visibility was shown to be non-inferior to an ultrathin-strutted bioresorbable polymer-coated sirolimus-eluting stent (Orsiro) that uses a cobalt-chromium strut platform.

Findings of the BIONYX trial were reported today at the 30th annual Transcatheter Cardiovascular Therapeutics (TCT) scientific symposium. Sponsored by the Cardiovascular Research Foundation (CRF), TCT is the world's premier educational meeting specializing in interventional cardiovascular medicine. The study was also published simultaneously in The Lancet.

"The vast majority of contemporary stents use stent platforms from cobalt-chromium alloy which allows for the creation of fine mesh tubes with satisfactory radial force, but limited x-ray visibility," said Clemens von Birgelen, MD, PhD, an Interventional Cardiologist at Thoraxcentrum Twente and Professor of Interventional Cardiology at the University of Twente in Enschede, The Netherlands. "Sub-optimal radiographic visibility can be challenging in obese patients, when treating bifurcated or calcified coronary lesions, or when carefully assessing stent expansion."

The Resolute Onyx stent was developed in response to the demand for stents with better radiographic visibility which may facilitate the recognition of stents that are not yet well expanded or incompletely apposed to the arterial wall. The stent uses a novel thin strut composite wire stent platform, covered with a zotarolimus-eluting durable polymer coating. The metallic stent platform consists of a composite wire made from a dense platinum-iridium core, which makes the struts radiopaque, and an outer layer of cobalt-chromium alloy. The dense core also allows for a somewhat lower strut thickness. A head-to-head comparison with the Orsiro stent was of interest, as the Orsiro has shown excellent efficacy and safety outcomes in multiple randomized clinical trials, including three large-scale trials in all-comers.

Between October 7, 2015, and December 23, 2016, a total of 2,488 all-comer patients were included in the intention-to-treat analysis. Participants were between 30 and 96 years of age, 594 (23.9%) were women, 1,765 (70.9%) presented with an acute coronary syndrome, and 1,275 (51.2%) were treated for an acute myocardial infarction at the time of study enrollment.

At one-year follow-up, the primary endpoint of target vessel failure was met by 55 (4.5%) of 1,243 patients assigned to Resolute Onyx, and by 58 (4.7%) of 1,245 assigned to Orsiro. Non-inferiority of Resolute Onyx versus Orsiro was established with an absolute risk difference of -0.2% (95% CI -1.9-1.4) and an upper limit of the one-sided 95% CI of 1.1% (pnon-inferiority=0.0005, psuperiority=0.77).

The rates of cardiac death, target vessel-related myocardial infarction, and clinically indicated target vessel revascularization were low and similar in both groups. Definite or probable stent thrombosis occurred in a single patient (0.1%) in the Resolute Onyx group and nine patients (0.7%) in the Orsiro group (HR 0.11 [95% CI 0.01-0.87], p=0.0112).

"Despite the difference in stent strut materials and thicknesses and the dissimilar durable and bioresorbable polymer coatings of the two study stents, the BIONYX study found no advantage for one stent over the other," added von Birgelen. "Treatment with both stents was similarly safe and effective with excellent one-year clinical outcomes in a complex all-comer patient population. The observed very low stent thrombosis rate in Resolute Onyx warrants further clinical investigation."

Comments

The opinions expressed here are the views of the writer and do not necessarily reflect the views and opinions of News Medical.
Post a new comment
Post

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.

You might also like...
New stent sensor developed to detect blockages early