Revolutionary, portable device can provide continuous blood pressure measurements

Researchers at Monash University are on the verge of creating a revolutionary, portable blood pressure monitoring device that can provide data continuously to patients from the comfort of their home.

In a world-first study, led by Associate Professor Mehmet Yuce from Monash University's Department of Electrical and Computer Systems Engineering, 43 Australian participants trialed a wireless blood pressure monitoring device, developed by the research team, which provided continual readings across a 24-hour period.

Data was recorded during a range of sedentary and physical activities during the participants' regular day. Results were published in the prestigious international journal Nature Scientific Reports.

Blood pressure abnormalities, such as hypertension and hypotension, are important risk factors for many critical short- and long-term illnesses, with a global disease burden of 1.25 billion people. The current gold standard for blood pressure measurement is the cuffed sphygmomanometer, commonly seen at GP clinics and hospitals.

For close to a century, the health sector has used the cuff device to measure blood pressure. More invasive measures are used to monitor the continuous blood pressure of critically ill patients, which are uncomfortable and could potentially cause infection due to ischemia."

Mehmet Yuce, Associate Professor, Monash University

Researchers used continuous wave radar (CWR) and photoplethysmogram (PPG) sensors to calculate continuous blood pressure measurements. The CWR and PPG sensors were placed on the sternum and left earlobe respectively.

By using radar technology, researchers were able to calculate the pre-ejection period (PEP) - the mechanical delay associated with heart movements ejecting the blood - and the pulse transit time to estimate blood pressure in patients while sitting, laying down or exercising.

Results on subjects participating in posture tasks were 93 per cent accurate, while those performing exercises achieved an 83 per cent success rate.

Associate Professor Yuce and his research team have developed several prototypes of the blood pressure device, and will conduct further tests to make it more accurate and suitable for clinical use.

"Clinicians still cannot continuously measure blood pressure during sleep, nor during times of activity such as walking or running. This means people with high, low or irregular blood pressure can't get the critical information they need about the state of their health around the clock," Associate Professor Yuce said.

"A wearable device that can provide comfort and portability while people are going about their daily lives will be a significant development for the health sector in Australia and internationally."

A trial was conducted on 43 participants, between the ages of 40 and 65, with no previous cardiovascular problems. Participants wore both the cuff device and the chest-based prototype to monitor the difference between blood pressure readings.

Blood pressure data was recorded on all participants while sitting, standing and laying in the supine position (facing upwards). Subsequent tests were also conducted with patients holding a handgrip for two minutes; cycling at a fixed speed across three different resistance levels; and at the recovery stage after the cycling tasks.

The technology has the capability of providing real-time access to data, and give doctors an overview of how their patients' blood pressure changes over the course of a day, rather than at the time of testing.

"The CWR sensors present a low-power, continuous and potentially wearable system with minimal body contact to monitor aortic valve activities directly. Doctors would be interested to see such information for long-term better diagnosis of their patients," Associate Professor Yuce said.

"Results of this study demonstrate the potential superiority of CWR-based PEP extraction for various medical monitoring applications, including blood pressure monitoring."

Blood Pressure - New Device
Source:
Journal reference:

Ebrahim, M.P., et al. (2019) Blood Pressure Estimation Using On-body Continuous Wave Radar and Photoplethysmogram in Various Posture and Exercise Conditions. Scientific Reports. doi.org/10.1038/s41598-019-52710-8.

Comments

The opinions expressed here are the views of the writer and do not necessarily reflect the views and opinions of News Medical.
Post a new comment
Post

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.

You might also like...
Blood count stability reveals new pathways to personalized care