The Avanti® J-26S centrifuge series is the only high-performance system you’ll ever need. Experience simplified high-throughput sample processing and more control with powerful features including low heat output, imbalance tolerance and quiet performance.
- Easy to operate
- Built-in safety features
- Application versatility
Features
Application Versatility
- Process six liters of fermentor output in less than 10 minutes
- Deliver a subcellular fraction at 82,000 x g
- Run 24 microplates at a time
- Separate live cell populations with elutriation
Complete BioSafety* systems for ultimate peace of mind
- BioCertified** rotors, instruments and labware with microbiological aerosols
- Sterile filters prevent discharge of infectious materials
Dual-System Rotor Recognition for operator safety
- Automatically detect which rotor is installed
- Prevent rotors from running above maximum-rated speeds while maintaining the run
- Friction Reduction System for faster, quieter and more energy-efficient runs
- Lightweight J-Lite Rotors for reduced run times and high g-force
- Ergonomic Earth-Friendly Design
- Optimal working surface height for easier loading and unloading of rotors
- Each instrument saves approximately 9.6 pounds of post-consumer materials from the landfill
Avanti J-26S XP and J-26S XPI Features Overview
Feature
|
Avanti J-26S XPI
|
Avanti J-26S XP
|
User-defined programs
|
30 two-step pre-written programs
|
NONE
|
Time settings
|
1 min – 99+ hours; Hold
|
1-180 mins; Hold
|
Acceleration rates
|
12 plus max
|
2 plus max
|
Deceleration rates
|
3 plus max
|
3 plus max
|
Simultaneous display of set and operative parameters
|
YES
|
NONE
|
Delayed start
|
YES
|
NONE
|
Continuous flow; Zonal; Elutriation capability
|
YES
|
NONE
|
Key lock-out
|
YES
|
NONE
|
Instrument Specifications
Avanti J-26S Centrifuge System Specifications
UNSPSC
|
41103905
|
Height
|
86 cm (34 in); with door open 149 cm (58.5 in)
|
Width
|
71 cm (28 in)
|
Depth
|
86 cm (34 in); 102 cm (40.25 in) (including air diverter extending from back panel)
|
Weight
|
290 kg (640 lbs)
|
Friction Reduction System (FRS)
|
Mechanical rotary vane pump reduces chamber pressure to 0.25 ATM (190 mm [7.5 in] Hg)
|
Max capacity volume range
|
6 Liters
|
Max speed
|
26,000 rpm
|
Noise level (0.91meters /3' in front of centrifuge)
|
57 dBA
|
Max heat dissipation into room (steady-state conditions)
|
2.0 kW (6,900 BTU/hr)
|
Rotor ID
|
Automatic
|
Set temperature
|
-10° C to +40° C (in 1° C increments)
|
Set time
|
1 Min - 3 Hours, Continuous Hold
|
Refrigeration system
|
Non-CFC, non-ozone depleting refrigerant
|
Speed control
|
± 10 rpm of set speed or 0.1%, whichever is greater
|
Speed range
|
100 to 26,000 rpm or equivalent RCF; 0 to 5,000 rpm for elutriation
|
Temperature control
|
± 2° C of set temperature (after equilibration)
|
Zonal capability
|
Yes
|
Single tube sample volume range
|
1.8 - 1,000 mL
|
Ambient temperature range
|
16° C to 38° C
|
Clearances required
|
7.6 cm (3.0 in) sides; 16.0 cm (6.25 in) rear
|
Door
|
6.1 cm (2.4 in) thick plastic resin with steel plate
|
Humidity restrictions
|
< 95% (noncondensing)
|
Pollution degree
|
2
|
Rotor chamber diameter
|
51.3 cm (20 in)
|
Time–actual display
|
Indicates run time remaining (timed run) or elapsed time (hold run)
|
Maximum force at r max (g)
|
82,000 x g
|
Accelertion
|
Maximum, Slow
|
Deceleration
|
Maximum, Slow, Off
|