The Olympus FluoView® FVMPE-RS, a dedicated multiphoton microscope system, enables high-precision, ultra-fast scanning and stimulation, allowing researchers to see deep within specimens, take measurements at the highest speeds, and capture images even when working under the most demanding conditions.

With its high speed and precision performance, the FVMPE-RS is designed for electrophysiology and optogenetics studies. It is also a good match for applications such as high-speed calcium and in vivo imaging, peristalsis and blood flow studies, mosaic imaging, connectomics and functional brain imaging, stem cell research, and any field that requires precise colocalization, uncaging, simultaneous imaging/stimulation, extensive real-time signal processing, or multipoint mapping. Its design offers ready adaptability for researchers who design their own custom-built optical delivery as well.

The new system offers unmatched speed. The FVMPE-RS captures 438 frames per second (fps) at 512x32, the fastest rate commercially available. It also captures full-frame, 512x512 images at 30fps without any reduction of the field of view, a critical feature for many functional imaging studies. Its scanner unit combines a newly designed resonant scanner with a galvanometer scanner to provide both speed and excellent definition. The resonant scanner offers an exclusive non-linear sampling method for smooth imaging without intensity variation or image distortion, and greatly minimizes line jitter at any zoom factor. An optional third galvanometer scanner is also available for simultaneous imaging with 3D stimulation or uncaging in a given optical section. The system’s multipoint mapping capability allows ultra-high-speed stimulation along with measurement of rapid fluctuations in groups of cells for functional imaging studies, 3Dintensity measurement or mapping with high signal-to-noise performance.

In addition to speed, the FVMPE-RS offers optimal performance when imaging live cells and tissues. It provides multicolor, multiphoton excitation and imaging with a choice of lasers, along with an industry-first four-axis auto-alignment capability for precise colocalization and coalignment without pixel shift. With its multiple-laser-line performance, researchers can image with two colors at optimal wavelength excitation simultaneously while stimulating the sample with visible light, or image with one infrared (IR) laser while simultaneously stimulating with IR and/or visible light. The system delivers sharp images with clear separation of fluorescence proteins for analysis.

The high-sensitivity system offers excellent throughput from 400nm to 1600nm. New 1600 Coating technology provides industry-leading broadband transmission without sacrificing the ability to stimulate at lower wavelengths (such as 405nm for glutamate uncaging or 458nm for channelrhodopsin stimulation). The new coating allows the system to support the latest InSight lasers from Spectra-Physics®, providing researchers with the ability to image near-IR dyes such as Cy5 and Cy7. The Olympus line of 25x multiphoton optimized objectives also feature this new coating, and offer working distances of 2, 4 or 8mm to deliver super-deep imaging. Light collection efficiency is further improved by the FVMPE-RS system’s optimized light path. In Deep Focus Mode, researchers can adjust laser properties precisely to account for tissue scattering, helping optimize deep-tissue imaging by achieving signal improvements of 20 percent or more over comparable systems. An optional high-sensitivity cooled gallium arsenide phosphide (GaAsP) detector unit further enhances sensitivity while minimizing electrical noise, making the most out of the system’s high-speed capabilities.

The system’s precision timing allows for microsecond repeatability and control of multiple imaging and stimulation protocols, as well as millisecond repeatability over days of time-lapse imaging. Complex multi-position imaging or optogenetic stimulation protocols can be accomplished using the advanced stage control and sequence manager. The new system’s multichannel analog box for triggering, synchronization and signal input provides additional support for advanced electrophysiology studies and other applications requiring external device triggering. The advanced optional nosepiece piezo drive provides greater rigidity and faster z-plane stabilization to ensure accurate and repeatable high-speed focus performance.

The FVMPE-RS is designed to be simple to use and require minimal alignment, thanks to its robust auto-alignment system and easy touch-panel control. Enhanced temperature stability and a highly rigid frame make it an ideal foundation for live cell experiments.

A dedicated multiphoton system, the FVMPE-RS is compatible with Olympus’ industry-leading range of multiphoton specialty objectives, including the multi-award-winning 4mm and 8mm SCALEVIEW objectives and Olympus’ high-performance, 25x dedicated multiphoton objectives.

The system will be sold as part of the full line of Olympus advanced imaging microscope systems, including the FV1200 and FV1200MPE family of microscope systems. For more information on the Olympus FVMPE-RS multiphoton system, visit https://www.olympusamerica.com/ or contact Brendan Brinkman, Olympus America Inc., at 424-298-7402; email [email protected].

About Olympus America Inc., Scientific Equipment Group

Olympus America Scientific Equipment Group provides innovative microscope imaging solutions for researchers, doctors, clinicians and educators. Olympus microscope systems offer unsurpassed optics, superior construction and system versatility to meet the ever-changing needs of microscopists, paving the way for future advances in life science.

About Olympus

Olympus is a precision technology leader, designing and delivering innovative solutions in its core business areas: Medical and Surgical Products, Life Science Imaging Systems, Industrial Measurement and Imaging Instruments and Cameras and Audio Products. Olympus works collaboratively with its customers and affiliates worldwide to leverage R&D investment in precision technology and manufacturing processes across diverse business lines. These include:

  • Gastrointestinal endoscopes, accessories, and minimally invasive surgical products;
  • Advanced research, clinical and educational microscopes and research and educational digital imaging systems;
  • Industrial research, engineering, test, inspection and measuring instruments; and
  • Digital cameras and voice recorders.

Olympus serves the healthcare field with integrated product solutions and financial, educational and consulting services that help customers to efficiently, reliably and more easily achieve exceptional results. Olympus develops breakthrough technologies with revolutionary product design and functionality for the consumer and professional photography markets, and also is the leader in gastrointestinal endoscopy and clinical and educational microscopes. For more information, visit www.olympusamerica.com.

Citations

Please use one of the following formats to cite this article in your essay, paper or report:

  • APA

    Evident Corporation - Life Sciences. (2023, March 22). Functional brain mapping and high speed physiology multiphoton system from Olympus. News-Medical. Retrieved on December 22, 2024 from https://www.news-medical.net/news/20130917/Functional-brain-mapping-and-high-speed-physiology-multiphoton-system-from-Olympus.aspx.

  • MLA

    Evident Corporation - Life Sciences. "Functional brain mapping and high speed physiology multiphoton system from Olympus". News-Medical. 22 December 2024. <https://www.news-medical.net/news/20130917/Functional-brain-mapping-and-high-speed-physiology-multiphoton-system-from-Olympus.aspx>.

  • Chicago

    Evident Corporation - Life Sciences. "Functional brain mapping and high speed physiology multiphoton system from Olympus". News-Medical. https://www.news-medical.net/news/20130917/Functional-brain-mapping-and-high-speed-physiology-multiphoton-system-from-Olympus.aspx. (accessed December 22, 2024).

  • Harvard

    Evident Corporation - Life Sciences. 2023. Functional brain mapping and high speed physiology multiphoton system from Olympus. News-Medical, viewed 22 December 2024, https://www.news-medical.net/news/20130917/Functional-brain-mapping-and-high-speed-physiology-multiphoton-system-from-Olympus.aspx.

Comments

The opinions expressed here are the views of the writer and do not necessarily reflect the views and opinions of News Medical.
Post a new comment
Post

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.

You might also like...
EVIDENT Announces 2021 Global Image of the Year Award Winners