Shimmer develops algorithm to obtain mobility data from foot sensors

Shimmer has developed an algorithm to obtain mobility data from a Shimmer3 sensor (accel + gyro) placed on a shoe. This algorithm is based on state of the art wearable sensor/biomechanics research and has already been tested on a young, healthy data-set in order to obtain normative standards to compare metrics to.

This algorithm is ideal for applications in the area of sensors embedded into shoes, or applications that could be used for remote monitoring or supervised monitoring, such as in a clinic or care-home.

The below information gives an overview of the algorithm, as well as data vizualizations for the normative data that has been collected to date:

Algorithm Summary

The Shimmer foot sensor algorithm has three levels of metrics:

Variable Type Metric Description
Temporal Stride time The time between foot strike on one foot to the next foot strike on the same foot. Represents one full gait cycle.
Kinematic Sagittal foot angle Sagittal plane foot angle during the gait cycle. Zero angle represents the angle of the foot during foot flat. Positive values represent a rotation with the toes going upward and negative represents a rotation with the heels going upward.
  Sagittal foot angle Frontal plane foot angle during the gait cycle.
Spatial Stride distance The distance from one foot placement to the next foot placement with the same foot
 

 

Data Visualizations

Stride time below:

Sagittal foot angle

 

Frontal Foot Angle

 

Anterior/ Posterior foot Velocity

 

Stride Distance

 

Normative gait data was obtained with 30 (16 female / 14 male) participants who performed twenty 12 m walking trials each.

You can find the normative data from these 30 participants in the table below:

Feature Unit Mean Max Min SD
Stride time Sec 1.08 1.28 0.91 0.09
Peak sagittal foot angle Deg 1.37 1.79 0.96 0.17
Min sagittal foot angle Deg -65.1 -30.9 -90.0 10.6
Max frontal foot angle Deg 14.3 44.2 0.0 12.0
Min frontal foot angle Deg -13.1 0.0 -43.3 11.1
Peak AP foot velocity m/sec 4.77 6.1 3.35 0.48
Stride length m 1.37 1.79 0.96 0.17
Normalized stride length m/cm 0.0113 0.0165 0.0074 0.0018

 

Citations

Please use one of the following formats to cite this article in your essay, paper or report:

  • APA

    Shimmer. (2019, June 20). Shimmer develops algorithm to obtain mobility data from foot sensors. News-Medical. Retrieved on November 28, 2024 from https://www.news-medical.net/news/20180331/Shimmer-develops-algorithm-to-obtain-mobility-data-from-foot-sensors.aspx.

  • MLA

    Shimmer. "Shimmer develops algorithm to obtain mobility data from foot sensors". News-Medical. 28 November 2024. <https://www.news-medical.net/news/20180331/Shimmer-develops-algorithm-to-obtain-mobility-data-from-foot-sensors.aspx>.

  • Chicago

    Shimmer. "Shimmer develops algorithm to obtain mobility data from foot sensors". News-Medical. https://www.news-medical.net/news/20180331/Shimmer-develops-algorithm-to-obtain-mobility-data-from-foot-sensors.aspx. (accessed November 28, 2024).

  • Harvard

    Shimmer. 2019. Shimmer develops algorithm to obtain mobility data from foot sensors. News-Medical, viewed 28 November 2024, https://www.news-medical.net/news/20180331/Shimmer-develops-algorithm-to-obtain-mobility-data-from-foot-sensors.aspx.

Comments

The opinions expressed here are the views of the writer and do not necessarily reflect the views and opinions of News Medical.
Post a new comment
Post

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.

You might also like...
Study examines use of IMU sensors for biofeedback in strength and conditioning training