FDA approves first spinal tether device to treat children with idiopathic scoliosis

The U.S. Food and Drug Administration today approved the first spinal tether device intended to be used in children and adolescents to correct the most common form of scoliosis, called idiopathic scoliosis, that has not responded to conservative treatment options, such as external bracing. The device, called The Tether - Vertebral Body Tethering System, is intended to treat growing children and adolescents whose spinal curves are approaching or have reached the range where surgical treatment is an option.

For children and adolescent patients with idiopathic scoliosis that does not respond favorably to bracing, treatment options have been limited to fusion surgeries. Today's approval provides access to a new treatment option that could improve quality of life for patients with idiopathic scoliosis."

Capt. Raquel Peat, Ph.D., director of the Office of Orthopedic Devices in the FDA's Center for Devices and Radiological Health

Idiopathic scoliosis is a sideways curvature of the spine whose cause is unknown. It is the most common spinal deformity in children and is most often diagnosed between ages 10 to 18, although it may occur at a younger age. The standard treatments for idiopathic scoliosis among children and adolescents who are still growing are conservative, non-surgical treatments such as external bracing to help correct the spinal curvature. Approximately 6,800 patients in the U.S. each year will develop progressive curvatures that do not respond to bracing. For these patients, spinal fusion surgery (i.e., spinal implants to correct the curvature of the spine and fusion surgery) may be used to permanently stabilize and correct spinal curvatures. While spinal fusion is often successful, this surgery permanently restricts the motion of the spine and may have long-term complications such as pain, arthritis and future spinal deformities, which could require additional surgical treatment.

The Tether - Vertebral Body Tethering System provides an alternative for patients with idiopathic scoliosis that doesn't respond to bracing. As a patient grows, The Tether - Vertebral Body Tethering System is designed to continue to correct the curvature while maintaining a fuller range of motion when compared to spinal fusion procedures.

The Tether - Vertebral Body Tethering System includes anchors and vertebral body screws that are placed into the same side of each vertebra in the curved section of the spine through an incision on the side of the chest. A flexible cord, called a tether, is connected to the screws. Tension is applied to the tether during surgery to compress one side of the spine and to partially correct the curve. Over time, the tether slows growth on the curved side of the spine and promotes growth on the opposite side. This provides additional correction of the curve as the patient continues to grow. The Tether - Vertebral Body Tethering System is not intended to be removed unless certain problems, such as overcorrections, develop. Health care professionals will monitor patients, conducting follow-up x-rays, to track the spinal curvature and identify any potential problems that might require additional surgery to revise or remove the device. For those patients whose curves are not adequately corrected by The Tether - Vertebral Body Tethering System, spinal fusion surgery is still possible.

The FDA reviewed data for The Tether - Vertebral Body Tethering System through the humanitarian device exemption (HDE) process. A Humanitarian Use Device (HUD) is a device intended to benefit to patients by treating or diagnosing a disease or condition that affects not more than 8,000 individuals in the U.S. per year.

The FDA reviewed clinical data supporting the safety and probable benefit of The Tether - Vertebral Body Tethering System from 57 patients who received the device. At two years, 43 patients had sufficient improvement of the curvature of their spines and did not need spinal fusion. The most common serious adverse events observed included overcorrection of the curvature, tether breakage, and pneumothorax or air leakage into the space between the lung and chest wall. General complications consistent with any spinal surgical procedure were also noted including pain, respiratory problems, nerve injuries and bleeding.

Zimmer Biomet Spine has shared with the FDA that it will be partnering with the Harms Study Group, a cohort of surgeons dedicated to the advancement of treatment for children and adolescents with spinal deformities, to develop a patient data registry to help assess the long-term performance of The Tether System.

The FDA continues to collaborate with stakeholders to encourage the development of registries, including the one being developed for this device, as an additional tool to gather and track real world evidence. This type of post-market data generation can provide ongoing device safety surveillance and additional evidence for effectiveness. More broadly, real world evidence can help support innovative developments while ensuring that patient health and safety remains the top priority."

FDA Principal Deputy Commissioner Amy Abernethy, M.D., Ph.D

The FDA granted the approval of The Tether - Vertebral Body Tethering System to Zimmer Biomet Spine.

Comments

The opinions expressed here are the views of the writer and do not necessarily reflect the views and opinions of News Medical.
Post a new comment
Post

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.

You might also like...
Pfizer-BioNTech vaccine provides strong protection against MIS-C in children aged 5–17