New exosome-coated stent repairs damaged tissue, heals vascular injury

Researchers from North Carolina State University have developed an exosome-coated stent with a "smart-release" trigger that could both prevent reopened blood vessels from narrowing and deliver regenerative stem cell-derived therapy to blood-starved, or ischemic, tissue.

Angioplasty - a procedure that opens blocked arteries - often involves placing a metal stent to reinforce arterial walls and prevent them from collapsing once the blockage is removed. However, the stent's placement usually causes some injury to the blood vessel wall, which stimulates smooth muscle cells to proliferate and migrate to the site in an attempt to repair the injury. The result is restenosis: a re-narrowing of the blood vessel previously opened by angioplasty.

"The inflammatory response that stents cause can decrease their benefit," says Ke Cheng, corresponding author of the research. "Ideally, if we could stop smooth muscle cells from over-reacting and proliferating, but recruit endothelial cells to cover the stent, it would mitigate the inflammatory response and prevent restenosis." Cheng is the Randall B. Terry Jr. Distinguished Professor in Regenerative Medicine at NC State and a professor in the NC State/UNC-Chapel Hill Joint Department of Biomedical Engineering.

There are drug-eluting stents currently in use coated with drugs that discourage cell proliferation, but these anti-proliferative drugs also delay stent coverage by endothelial cells - which are the cells healthcare providers want to coat the stent.

To solve this problem, Cheng and his team developed a stent coating composed of exosomes derived from mesenchymal stem cells. Exosomes are tiny nano-sized sacs secreted by most cell types. The idea behind the coating was two-fold: first, since the exosomes are composed of materials not much different from cell membranes they 'camouflage' the stent to trick smooth muscle cells and the body's immune system. Second, the exosomes promote coverage of the stent by endothelial cells and, in the case of injury, travel downstream to the site to promote tissue repair.

To prevent premature depletion of the therapy, the stent releases exosomes when it encounters reactive oxygen species (ROS) - which are more prevalent during an inflammatory response.

"Think of it as a smart release function for the exosomes," Cheng says. "Ischemic reperfusion injuries, which occur when blood flow is diminished and then reestablished, create a lot of ROS. Let's say the heart is damaged by ischemia. The enhanced ROS will trigger the release of the exosomes on the stent, and regenerative therapy will travel through the blood vessel to the site of the injury."

The research team performed in vitro testing to ensure biocompatibility and test the release mechanism. They found that in the presence of ROS, the exosomes released up to 60% of their secretions within 48 hours post-injury.

In a rat model of ischemic injury, the researchers compared their exosome-eluting stent (EES) to both a bare metal stent (BMS) and a drug-eluting stent (DES). They found that in comparison to the BMS, their stent performed better in both decreasing stenosis and promoting endothelial coverage.

While the DES performed similarly to the EES in preventing restenosis, the EES was less injurious to the vessel wall and had better endothelial coverage overall. In addition, the exosomes released from EES promoted muscle regeneration in rats with hind limb ischemia. The researchers plan to test the stent in a large animal model with an eye toward eventual clinical trials.

This bioactive stent promotes vascular healing and ischemic repair, and a patient wouldn't need additional procedures for regenerative therapy after the stent is in place. The stent is the perfect carrier for exosomes, and the exosomes make the stent safer and more potent in tissue repair."

Ke Cheng, Study Corresponding Author and Randall B. Terry Jr. Distinguished Professor in Regenerative Medicine, North Carolina State University

Source:
Journal reference:

Hu, S., et al. (2021) Reopen and Regenerate: Exosome-Coated Stent Heals Vascular Injury, Repairs Damaged Tissue. Nature Biomedical Engineering. doi.org/10.1038/s41551-021-00705-0.

Comments

The opinions expressed here are the views of the writer and do not necessarily reflect the views and opinions of News Medical.
Post a new comment
Post

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.

You might also like...
Understanding cardiovascular risks in endometriosis patients