Contrast-enhanced in-phase Dixon shows higher sensitivity for detecting breast biopsy clips on MRI

According to ARRS' American Journal of Roentgenology (AJR), the contrast-enhanced in-phase Dixon sequence could reduce the need for correlation among other imaging modalities to better identify areas of prior biopsy during breast MRI interpretation.

Compared with clinical sequences, contrast-enhanced in-phase Dixon had higher sensitivity for detecting breast biopsy clips on MRI, as well as higher reader confidence and contrast-to-noise ratio (CNR), without change in positive predictive value (PPV)."

Michael W. Taylor-Cho, MD, MPH, corresponding and co-first author, Duke University Medical Center in Durham, NC

Dr. Taylor-Cho and team's retrospective study numbered 164 women (mean age, 50.3 years) with a total of 281 breast biopsy clips who underwent contrast-enhanced breast MRI between January 2, 2019, and April 16, 2020. Blinded to patient identifiers, sequence information, and biopsy clip details, three radiologists independently annotated their findings on three clinical sequences-;T1-weighted (T1W) non-fat-suppressed (NFS), STIR, first phase from dynamic contrast-enhanced T1W fat-suppressed (FS) -;as well as contrast-enhanced in-phase Dixon. Confidence was then recorded on a scale of 1–4.

Ultimately, compared with T1W NSF, STIR, and T1WFS sequences, the contrast-enhanced in-phase Dixon sequence evidenced the highest sensitivity for breast biopsy clip detection (85.1% vs. 26.6%-78.2%), highest reader confidence (3.5 vs. 1.7–3.0), and highest CNR (4.05 vs 0.54–1.21), without a significant difference in PPV (96.4% vs. 92.2%–96.1%).

Employing this contrast-enhanced in-phase Dixon sequence may "help address a current challenge in routine clinical breast MRI interpretation," the authors of this AJR article concluded.

Source:
Journal reference:

Taylor-Cho, M.W., et al. (2022) Contrast-Enhanced In-Phase Dixon Sequence: Impact on Biopsy Clip Detection on Breast MRI. American Journal of Roentgenology. doi.org/10.2214/AJR.22.28024.

Comments

The opinions expressed here are the views of the writer and do not necessarily reflect the views and opinions of News Medical.
Post a new comment
Post

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.

You might also like...
New AI tool maps millions of CD8+ T cells to advance disease research