The Thermal Analysis System TGA/DSC 3+ provides unmatched performance.

Outstanding weighing performance

No other TGA can continually measure up to 50 million points. With a resolution of 0.1 μg, up to 5 g can be measured, depending on the type of balance.

Lowest minimum weight on all balances

A low minimum weight ensures the accurate weighing of small samples toward the low end of the weighing range.

DSC Heat Flow measurement

The TGA/DSC 3+ can be outfitted with an SDTA, DTA, or DSC sensor to simultaneously detect thermal effects that do not result in weight loss.

Features

Mettler-Toledo Ultra-Micro balance

High-performance DSC 3+

Image Credit: Mettler-Toledo International Inc.

Rely on the balance technology leader.

Wide temperature range

High-performance DSC 3+

Image Credit: Mettler-Toledo International Inc.

Examine samples that have been exposed to ambient temperatures up to 1600 °C.

DSC Heat flow measurement

High-performance DSC 3+

Image Credit: Mettler-Toledo International Inc.

For the simultaneous identification of thermal effects.

Built-in gas flow control

High-performance DSC 3+

Image Credit: Mettler-Toledo International Inc.

Examine the samples in specified environments.

Automated TGA-FTIR, TGA-MS, and TGA-GC/MS

High-performance DSC 3+

Image Credit: Mettler-Toledo International Inc.

Analyze evolved gases accurately using FTIR, MS, or GC-MS.

Factory endurance-tested sample robot

High-performance DSC 3+

Image Credit: Mettler-Toledo International Inc.

Work effectively and reliably around the clock.

Modular concept protects investment

High-performance DSC 3+

Image Credit: Mettler-Toledo International Inc.

Fits both current and future requirements.

Specifications

Specifications - Thermal Analysis System TGA/DSC 3+. Source: Mettler-Toledo International Inc.

. .
Technique Differential Scanning Calorimetry (DSC)
Simultaneous Thermal Analyzer (TGA/DSC)
Thermogravimetry (TGA)
Applications Compositional Analysis
Crystallization
Glass Transition
Heat Capacity (cp)
Kinetics
Oxidation Induction Time (OIT)
Temperature Modulated DSC
Data Sampling 10 data pts / sec
Sensor Types DSC
DTA
SDTA
Temperature Range 22 °C – 1600 °C
Options FTIR
GC/MS
MS
Micro GC
Sorption
Vacuum
Signal Time Constant 15 s
Sensor Output Heat Flow
Mass
Cooling Rate (min) 0.02 K – 50 K
Heating Rate (/min) 0.02 K – 250 K (2 K – 250 K)

Other Equipment by this Supplier

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.