CDC scientists model the most efficient physical barrier against SARS-CoV-2 for worker protection

Size doesn’t matter — when it comes to physical barriers in the workplace. A new Centers for Disease Control and Prevention (CDC) study found larger barriers were not statistically better than smaller physical barriers in protecting against severe acute respiratory syndrome 2 (SARS-CoV-2).

SARS-CoV-2 spreads through the air, and new variants have made the virus even more transmissible. In response, many workplaces have erected physical and transparent barriers to block viral droplets.

The researchers write:

“This laboratory simulation showed that barriers reduced particle count by at least 71% for the smallest particles when located at least 9 cm (3.5”) above cough height.”

The CDC team suggests barriers that are 9 to 39 cm above cough height and at least 91 cm wide provide the best overall protection. In contrast, wider barriers and barriers higher than 39 cm above a customer’s mouth do not appear to improve barrier efficiency.

The study “Laboratory Study of Physical Barrier Efficiency for Worker Protection against SARS-CoV-2 while Standing or Sitting” was published on the preprint medRxiv* server prior to peer review.

This news article was a review of a preliminary scientific report that had not undergone peer-review at the time of publication. Since its initial publication, the scientific report has now been peer reviewed and accepted for publication in a Scientific Journal. Links to the preliminary and peer-reviewed reports are available in the Sources section at the bottom of this article. View Sources

Simulation of aerosol transmission

The researchers used a cough simulator to imitate a customer’s cough. There were nine transparent barriers of different sizes made up of acrylic sheets. In addition, a cough simulation was also performed with no barrier. Each simulation occurred in three 10-minute intervals.

The heights for the nine barriers were either 61, 91, or 122 cm. Their widths ranged from 61, 91, or 122 cm. Each barrier had a rectangular opening at the bottom center to model the space for transactions. This hole was 10 cm high and 31 cm wide.

Isolation Room 4.9 m (16’) long, 4.3 m (14 ‘ 2 ”) wide and 2.5 m (8’) tall. Note: the exhaust and supply vents were all on the ceiling (2.5 m). The supply closet door was open during the study.
Isolation Room 4.9 m (16’) long, 4.3 m (14 ‘ 2 ”) wide and 2.5 m (8’) tall. Note: the exhaust and supply vents were all on the ceiling (2.5 m). The supply closet door was open during the study.

An optical particle counter was placed on each side of a barrier for summing up the total amount of particles that move around the barrier.

Each of the nine barriers and the no barrier were conducted under simulations where two people would be sitting or standing. This represented typical workstations — customers sitting while getting a manicure in a nail salon and customers standing while checking out items at a grocery store.

Seated Interaction shown with a cough simulator, worker, and reference optical particle counters and transparent barrier. h indicates the height of the barrier, which was 61, 91 or 122 cm (24, 36 and 48”) from the table. The barrier widths, not shown, were 61, 91 or 122 cm (24, 36, and 48”). Table dimensions were 76 cm (30”) tall, 61 cm (24”) wide, and 102 cm (40”) long. A rectangular opening was cut into the bottom center of each barrier that was 10 cm (4”) tall and 31 cm (12”) wide.
Seated Interaction shown with a cough simulator, worker, and reference optical particle counters and transparent barrier. h indicates the height of the barrier, which was 61, 91 or 122 cm (24, 36 and 48”) from the table. The barrier widths, not shown, were 61, 91 or 122 cm (24, 36, and 48”). Table dimensions were 76 cm (30”) tall, 61 cm (24”) wide, and 102 cm (40”) long. A rectangular opening was cut into the bottom center of each barrier that was 10 cm (4”) tall and 31 cm (12”) wide.

Since more women than men visit a nail salon, the researchers configured the cough simulation at the seated mouth height of an average woman’s height. For the standing simulation, the cough simulator was positioned at a mouth height for an average height of a man.

The model simulation did not consider people moving around, which could affect how SARS-CoV-2 droplets move around the barrier.

Standing interaction with cough simulator, worker, and reference optical particle counters, and transparent barrier. h indicates the height of the barrier, which is 61, 91 or 122 cm (24, 36, and 48”) from the table. The barrier widths, not shown, were 61, 91 or 122 cm (24, 36, and 48”). Table dimensions were 91 cm (36”) high, 61 cm (24”) wide, and 102 cm (40”) long. A rectangular opening was cut into the bottom center of each barrier that was 10 cm (4”) tall and 31 cm (12”) wide.
Standing interaction with cough simulator, worker, and reference optical particle counters, and transparent barrier. h indicates the height of the barrier, which is 61, 91 or 122 cm (24, 36, and 48”) from the table. The barrier widths, not shown, were 61, 91 or 122 cm (24, 36, and 48”). Table dimensions were 91 cm (36”) high, 61 cm (24”) wide, and 102 cm (40”) long. A rectangular opening was cut into the bottom center of each barrier that was 10 cm (4”) tall and 31 cm (12”) wide.

Barrier size efficiency while standing

Regardless of width, having a barrier where the top was at least 14 cm above the coughing mouth while standing was 71% to 86% effective against small-sized particles than having no barrier.

Barriers were 68% to 87% against moderately sized particles when they were 14 cm above cough height standing.

A tall barrier consisting of 61 cm below cough height was not more efficient than having no barrier.

Barriers above cough height at minimally 91 cm wide had a 61% efficiency in protecting against large-sized particles.

Barrier size efficiency while sitting

A barrier at all heights and widths was 83% to 93% effective against small air particles while sitting.

Barriers that are at least 9 cm above cough height while sitting were 71% to 94% effective in blocking the passage of moderately sized particles.

Barriers that were at least 91 cm were approximately 69% effective against large-sized particles while sitting.

“Most barriers that were at least 14 cm (5.5“) above cough height in the standing scenario significantly blocked the aerosols relative to no barrier. In the sitting scenario, all barrier settings with moderate size outperformed no barrier by 86 to 93%,” concluded the researchers.

This news article was a review of a preliminary scientific report that had not undergone peer-review at the time of publication. Since its initial publication, the scientific report has now been peer reviewed and accepted for publication in a Scientific Journal. Links to the preliminary and peer-reviewed reports are available in the Sources section at the bottom of this article. View Sources

Journal references:

Article Revisions

  • Apr 11 2023 - The preprint preliminary research paper that this article was based upon was accepted for publication in a peer-reviewed Scientific Journal. This article was edited accordingly to include a link to the final peer-reviewed paper, now shown in the sources section.
Jocelyn Solis-Moreira

Written by

Jocelyn Solis-Moreira

Jocelyn Solis-Moreira graduated with a Bachelor's in Integrative Neuroscience, where she then pursued graduate research looking at the long-term effects of adolescent binge drinking on the brain's neurochemistry in adulthood.

Citations

Please use one of the following formats to cite this article in your essay, paper or report:

  • APA

    Solis-Moreira, Jocelyn. (2023, April 11). CDC scientists model the most efficient physical barrier against SARS-CoV-2 for worker protection. News-Medical. Retrieved on December 22, 2024 from https://www.news-medical.net/news/20210802/CDC-scientists-model-the-most-efficient-physical-barrier-against-SARS-CoV-2-for-worker-protection.aspx.

  • MLA

    Solis-Moreira, Jocelyn. "CDC scientists model the most efficient physical barrier against SARS-CoV-2 for worker protection". News-Medical. 22 December 2024. <https://www.news-medical.net/news/20210802/CDC-scientists-model-the-most-efficient-physical-barrier-against-SARS-CoV-2-for-worker-protection.aspx>.

  • Chicago

    Solis-Moreira, Jocelyn. "CDC scientists model the most efficient physical barrier against SARS-CoV-2 for worker protection". News-Medical. https://www.news-medical.net/news/20210802/CDC-scientists-model-the-most-efficient-physical-barrier-against-SARS-CoV-2-for-worker-protection.aspx. (accessed December 22, 2024).

  • Harvard

    Solis-Moreira, Jocelyn. 2023. CDC scientists model the most efficient physical barrier against SARS-CoV-2 for worker protection. News-Medical, viewed 22 December 2024, https://www.news-medical.net/news/20210802/CDC-scientists-model-the-most-efficient-physical-barrier-against-SARS-CoV-2-for-worker-protection.aspx.

Comments

The opinions expressed here are the views of the writer and do not necessarily reflect the views and opinions of News Medical.
Post a new comment
Post

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.

You might also like...
Polypurine hairpins found to effectively halt SARS-CoV-2 replication