The Hydrens team of researchers developed a numerical model that estimates the ozone concentration needed to meet the disinfection criteria. To do this, it takes into account the geometry and volume of the space to be treated, the type of materials inside it and their capacity to absorb ozone, and the characteristics of the impulsion-distribution system used.
To determine the amount of ozone required, the model also takes into account the barriers that the ozone may encounter, such as seats, bars, handles, etc. –which cause the gas to decompose when it hits them. As part of the ozone is lost in this way, this has to be allowed for when calculating the amount of gas necessary for proper disinfection. That is precisely what our model does."
Javier Navarro, Researcher, Department of Chemical and Nuclear Engineering, Valencia Polytechnic University
The catalyst is key
The model was validated through several tests, both in the laboratory and in metro and tram wagons –which were provided by Ferrocarrils de la Generalitat Valenciana, the Valencian Government railway company. An ozonisation system was installed in them that injected more and more gas, until it reached the concentration determined by the model. A catalyst for the decomposition of the residual ozone was installed too, in order to preventing its emission into the atmosphere.
"After disinfection, some residual ozone remains inside the wagons which has to be eliminated as quickly as possible, and that is what the catalyst that we at the ITQ provide does. In the tests that we have carried out, after applying the disinfection protocol that has been developed and taking our model into account, the residual ozone is eliminated through catalytic decomposition. In this way, the inside of the wagons remains free of ozone, and the emission of this gas into the atmosphere is prevented," says Antonio Chica, a senior CSIC scientist at the Institute of Chemical Technology (ITQ), a joint centre of the UPV and the CSIC.
The study team stresses that this procedure should be carried out when wagons are empty, with no passengers, starting with the injection of ozone and ending with the catalytic decomposition of the residual gas. Researchers also point out that using ozone in this way makes it possible to disinfect areas that cannot be disinfected with other methods –such as ultraviolet light, which does not reach every corner of the passenger compartment.
A system suitable for buses, aeroplanes...
"The efficacy of the system has been validated using porcine epidemic diarrhea virus (PEDV) and murine norovirus (MNV-1) as surrogates for SARS-CoV-2 and human norovirus, respectively. The results clearly support the use of ozone as an effective measure for virus inactivation in public transport. In laboratory-scale experiments, we achieved inactivation with ozone concentrations of 100 ppm for 25 min at 25 °C and 95% relative humidity. In a live test, we achieved the same inactivation efficiency with 55 ppm ozone for 20 min at 32 °C and 87% RH, which shows the relevance of humidity for inactivation efficiency," says Gloria Sánchez, the researcher in charge of the IATA-CSIC Environmental Virology and Food Safety Laboratory (VISAFELab).
Additionally, the UPV, CSIC, Hydrens, UJI and IATA team points out that, even though the experiments were carried out on real metro and tram wagons, the procedure that they developed can be extended to other vehicles such as buses and airplanes, and to interior spaces of buildings.
Source:
Journal reference:
Falcó, I., et al. (2021) Experimental and CFD evaluation of ozone efficacy against coronavirus and enteric virus contamination on public transport surfaces. Journal of Environmental Chemical Engineering. doi.org/10.1016/j.jece.2021.106217.