Study evaluates the clinical accuracy of two FDA-approved rapid antigen tests across SARS-CoV-2 variants

In a recent study posted to the medRxiv* preprint server, researchers evaluated clinical accuracy and analytical detection capabilities of the two US Food and Drug Administration (FDA)-approved rapid antigen tests (RATs) across severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) variants.

Study: Accuracy of Rapid Antigen Testing across SARS-CoV-2 Variants. Image Credit: Ian Gessey/Shutterstock
Study: Accuracy of Rapid Antigen Testing across SARS-CoV-2 Variants. Image Credit: Ian Gessey/Shutterstock

This news article was a review of a preliminary scientific report that had not undergone peer-review at the time of publication. Since its initial publication, the scientific report has now been peer reviewed and accepted for publication in a Scientific Journal. Links to the preliminary and peer-reviewed reports are available in the Sources section at the bottom of this article. View Sources

Background

They tested SCoV-2 Ag Detect™ Rapid Test and BinaxNOW™ COVID-19 Ag CARD against three replication-competent variants, including wild-type SARS-CoV-2 (USA-WA1/2020), Delta (B.1.617.2), and Omicron (B.1.1.529/BA.1).

RAT-generated results correlate with the abundance of replication-competent SARS-CoV-2 in the tested serum sample. If it retains accuracy across all SARS-CoV-2 variants, home-based RAT programs could help early detection of infected cases to reduce onward SARS-CoV-2 transmission.

About the study

In the present study, researchers obtained the Omicron isolate from nasopharyngeal swabs collected in Maryland in November 2021 through biodefense and emerging infections research resources repository (BEI). They cultured the virus on Cercopithecus aethiops kidney cells (Vero E6), expressing angiotensin-converting enzyme 2 (ACE2) and transmembrane protease serine 2 (TMPRSS2).

The research team confirmed the SARS-CoV-2 variant using whole-genome sequencing (WGS) and cross-referencing with the global initiative on sharing avian influenza data (GISAID). Likewise, they obtained the Delta (B.1.617.2) variant and SARS-CoV-2 USA-WA1/2020 strain.

They evaluated the replication competence of the virus stock for comparative analytical testing using a 50% tissue culture infectious dose (TCID50). Notably, the TCID50 values of Delta and USA-WA1/2020 are 1.1 x106 and 1.6 x106, respectively. They also determined a corresponding quantitative measure of infectious viral particles by assaying the plaque-forming units (PFUs) in infected Vero E6 cells following a standard plaque assay protocol.

They tested viral dilutions across variants in triplicates for the SCoV-2 Ag Detect™ Rapid Test and BinaxNOW™ COVID-19 Ag CARD, for which they used high, medium, and low viral concentrations (dilutions) of 1,000, 250, 62.5 TCID50 per swab, respectively. First, they established three stock viral concentrations of 5.0 x104, 1.25 x104, and 3.12 x103 TCID50/mL, and then they transferred 20 µL of sample onto nasal swabs to generate viral dilutions.

For testing the diagnostic accuracy of the SCoV-2 Ag Detect™ Rapid Test, they collected two anterior nasopharyngeal swab samples from 802 SARS-CoV-2-infected participants reporting onset of coronavirus disease 2019 (COVID-19) symptoms within the past five days. They collected test samples from multiple locations in King County, Washington, between February 2021 and January 2022. They tested one of the samples with reverse transcription-polymerase chain reaction (RT-PCR) and the other with RAT on-site.

The study duration of 12-months corresponded to the time phases, representing the community prevalence of different SARS-CoV-2 variants in the US, including Alpha/Beta, Delta, and Omicron.

Study findings

The analytical limit of detection or clinical diagnostic accuracy of RATs did not change significantly against any SARS-CoV-2 variants tested, including the Delta and Omicron VOCs. Based on the visual signal intensity associated with viral concentration, the limit of detection for the tested RATs was ~62.5 TCID50, equivalent to 51 PFUs, with more variation at low viral concentrations.

The positive percent agreement for the RATs was in the range of 81-91%, with improved sensitivity for swabs with lower cycle threshold (Ct) values, denoting a higher viral load. On the other hand, the negative percent agreement was high throughout the study.

Conclusions

The study provided clinical and analytical data to demonstrate that both BinaxNOW™ COVID-19 Ag CARD and SCoV-2 Ag Detect™ Rapid Test reliably detected several SARS-CoV-2 variants, including Delta and Omicron, among symptomatic COVID-19 cases. Additionally, the analytical limit of detection of these RATs showed insignificant differences across SARS-CoV-2 variants.

Overall, the RATs examined in the present study retained their clinical diagnostic accuracy against all SARS-CoV-2 variants and appeared unaffected by mutations in the SARS-CoV-2 genome and its evolution.

This news article was a review of a preliminary scientific report that had not undergone peer-review at the time of publication. Since its initial publication, the scientific report has now been peer reviewed and accepted for publication in a Scientific Journal. Links to the preliminary and peer-reviewed reports are available in the Sources section at the bottom of this article. View Sources

Journal references:

Article Revisions

  • May 12 2023 - The preprint preliminary research paper that this article was based upon was accepted for publication in a peer-reviewed Scientific Journal. This article was edited accordingly to include a link to the final peer-reviewed paper, now shown in the sources section.
Neha Mathur

Written by

Neha Mathur

Neha is a digital marketing professional based in Gurugram, India. She has a Master’s degree from the University of Rajasthan with a specialization in Biotechnology in 2008. She has experience in pre-clinical research as part of her research project in The Department of Toxicology at the prestigious Central Drug Research Institute (CDRI), Lucknow, India. She also holds a certification in C++ programming.

Citations

Please use one of the following formats to cite this article in your essay, paper or report:

  • APA

    Mathur, Neha. (2023, May 12). Study evaluates the clinical accuracy of two FDA-approved rapid antigen tests across SARS-CoV-2 variants. News-Medical. Retrieved on December 22, 2024 from https://www.news-medical.net/news/20220325/Study-evaluates-the-clinical-accuracy-of-two-FDA-approved-rapid-antigen-tests-across-SARS-CoV-2-variants.aspx.

  • MLA

    Mathur, Neha. "Study evaluates the clinical accuracy of two FDA-approved rapid antigen tests across SARS-CoV-2 variants". News-Medical. 22 December 2024. <https://www.news-medical.net/news/20220325/Study-evaluates-the-clinical-accuracy-of-two-FDA-approved-rapid-antigen-tests-across-SARS-CoV-2-variants.aspx>.

  • Chicago

    Mathur, Neha. "Study evaluates the clinical accuracy of two FDA-approved rapid antigen tests across SARS-CoV-2 variants". News-Medical. https://www.news-medical.net/news/20220325/Study-evaluates-the-clinical-accuracy-of-two-FDA-approved-rapid-antigen-tests-across-SARS-CoV-2-variants.aspx. (accessed December 22, 2024).

  • Harvard

    Mathur, Neha. 2023. Study evaluates the clinical accuracy of two FDA-approved rapid antigen tests across SARS-CoV-2 variants. News-Medical, viewed 22 December 2024, https://www.news-medical.net/news/20220325/Study-evaluates-the-clinical-accuracy-of-two-FDA-approved-rapid-antigen-tests-across-SARS-CoV-2-variants.aspx.

Comments

The opinions expressed here are the views of the writer and do not necessarily reflect the views and opinions of News Medical.
Post a new comment
Post

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.

You might also like...
Reinstating masking curbs hospital viral outbreaks, study confirms