A revolutionary electronic skin fabrication process brings us closer to a sixth 'magnetic perception' sense

In a recent study published in the journal Microsystems & Nanoengineering, researchers describe a groundbreaking novel fabrication process for a touchless interactive device ('skin') using a flexible giant magnetoresistive (GMR) sensor array. Current-generation flexible magnetoelectronic skins suffer from three fundamental shortcomings: low sensitivity, non-destructive delamination (fabrication) challenges, and minor magnetic field detection difficulties.

The current work addresses these shortcomings by presenting a novel electrochemical delamination process that produces an ultra-thin, multilayer GMR system that maintains performance even after repeated bending (up to 90 degrees). Test devices using this fabrication process demonstrated significant improvements over conventional systems in durability (especially bending-associated), pressure sensing, and non-contact interaction. This work represents the first step towards a new generation of high-performance flexible magnetic sensors, paving the way for more sophisticated wearable skin technologies.

a Illustration of a typical electrochemical delamination process. b Illustration of a PI-electronic foil preparation on a low-resistance silicon wafer in an NaCl solution. The NaCl solution climbs upward, facilitating the occurrence of reactions. c Schematic diagram of the electrochemical reactions at the cathode and anode. d Photographs showing the progress in the detachment of a 1.6 cm × 1.6 cm GMR sensor. e Average delamination time when applying a voltage ranging from 10 to 20 V; f Average delamination time when the NaCl concentration increases from 0.02 M to 5.43 M (supersaturation)a Illustration of a typical electrochemical delamination process. b Illustration of a PI-electronic foil preparation on a low-resistance silicon wafer in an NaCl solution. The NaCl solution climbs upward, facilitating the occurrence of reactions. c Schematic diagram of the electrochemical reactions at the cathode and anode. d Photographs showing the progress in the detachment of a 1.6 cm × 1.6 cm GMR sensor. e Average delamination time when applying a voltage ranging from 10 to 20 V; f Average delamination time when the NaCl concentration increases from 0.02 M to 5.43 M (supersaturation)

Background

The past two decades have witnessed unprecedented surges in the usage and applications of electronic wearables, particularly in the sphere of human-to-machine interfaces (HMIs). One such application, 'electronic skins,' aims to replicate natural skin functionality with added health monitoring and movement tracking capabilities. Current research seeks to augment this functionality by enabling the development of 'magnetic perception,' a novel 'sixth sense.'

This functionality is achieved using giant magnetoresistive (GMR) sensors composed of tunneling magnetoresistive (TMR), giant magnetoimpedance (GMI), anisotropic magnetoresistive (AMR), or Hall sensors. Unfortunately, conventional fabrication processes involving depositing Co/Cu, Py/Cu, or Pd/Co stacks onto ultrathin foils present multiple shortcomings. Notably, the fabrication process is often manual and inefficient, preventing standardized mass production. Furthermore, devices based on the finished product demonstrate low sensitivity to weak magnetic fields and low durability.

About the study

The present study aims to overcome these challenges by demonstrating the fabrication and performance of a novel electrochemical delamination process that allows for the non-destructive detachment of ultrathin films from their rigid substrate. This process not only enhances efficiency but also minimizes damage, resulting in a GMR spin valve structure with high magnetic sensitivity, a bending angle of 90°, and no observable performance degradation even after repeat bending.

Fabrication

Fabrication of the novel GMR sensor is achieved using a multistep electrochemical delamination procedure. First, a substrate comprised of a heavily doped silicon (Si) wafer (resistivity = 0.002 to 0.004 Ω cm) with a superimposed thin polymer layer is developed. Secondly, conventional microfabrication processes are used to fabricate GMR devices on the polymer layer. Thirdly, the construct is introduced into a sodium chloride (NaCl) electrolyte aqueous solution, and the edges of the polymer layer are trimmed to allow direct contact between the Si wafer and the NaCl solution.

a Schematic image showing the touchless interactions using the flexible GMR sensor array. b Optical image of the flexible GMR sensor array and magnetic skin on a human fingertip. c Magnetic response of the GMR sensor array when a finger approaches the top left corner. d Schematic images showing the pressure sensing using the flexible GMR sensor array. e, h Optical images of the flexible GMR sensor array and magnetic skin when pressures of 61.36 g and 180.89 g are applied. g Optical side images of the pressure sensing installation. f, i Magnetic response when pressures of 61.36 g and 180.89 g are applieda Schematic image showing the touchless interactions using the flexible GMR sensor array. b Optical image of the flexible GMR sensor array and magnetic skin on a human fingertip. c Magnetic response of the GMR sensor array when a finger approaches the top left corner. d Schematic images showing the pressure sensing using the flexible GMR sensor array. eh Optical images of the flexible GMR sensor array and magnetic skin when pressures of 61.36 g and 180.89 g are applied. g Optical side images of the pressure sensing installation. fi Magnetic response when pressures of 61.36 g and 180.89 g are applied

Finally, applying a positive and negative potential to the NaCl solution triggers an anodic reaction, resulting in the formation of oxygen (O2) bubbles that, in turn, facilitate the separation of the Si and polymer layers. Notably, this process can be automated and is devoid of mechanical and chemical damage characteristic of conventional GMR manufacturing approaches.

"This method demonstrates superiority over other delamination techniques due to its distinctly straightforward, notably rapid, noninvasive, and adaptable nature."

The free-standing polymer film thus obtained can easily be laminated onto target surfaces for the creation of GMR multilayer structures and the subsequent development of HMIs.

Performance

A magnetic resonance (MR) sensor testing platform was used for pilot device performance testing. GMR ratios were observed to reach 5.6%, matching conventional antiferromagnetic layer-based GMR devices. Following delamination, GMR ratios decreased to 2.46%. However, low magnetic field sensitivity significantly outperformed previous methodologies (10 Oe before and 80 Oe following delamination versus 4 kOe).

The surface roughness of the spin-coated polyimide was assessed using atomic force microscopy (AFM) and was revealed to be 0.574 nm. Comparisons of device curves before and after delamination were observed to be near-identical, confirming that the present delamination process had a close-to-no impact on final GMR performance.

Bending performance was evaluated using a custom-designed flexible circuit board. The GMR ratio was observed to remain at 2.46% across bending angles from 0° to 90° with resistance fluctuating by less than 6 Ω (initial resistance = 1600 Ω), further underscoring the device's durability.

"These attributes collectively indicated that the GMR system could be affixed to any part of the human body and remain unaffected by natural skin curvature; thus, this system is particularly valuable for applications in smart skin and biomedical contexts. Furthermore, due to its ultrathin and flexible nature, the GMR system could adhere to any flat surface, providing potential applications in diverse fields, including robotics and electronic power transmission."

The long-term stability of the GMR device was evaluated using repetitive loading experiments. Results revealed that even after 500 loading cycles (0° to 60° bending angles), the GMR ratio remained constant at 2.46%, highlighting that the GMR device remained stable despite repeated bending. Finally, the application of the GMR device as a magnetic skin capable of providing users with a sixth 'magnetic perception' sense was successfully evaluated.

"…it can be used on the human body for multisite pressure, particularly in patients at risk for pressure injuries, or applied to robots to provide high-resolution pressure sensing capabilities and human-like functionality."

Conclusions

The current study describes a revolutionary manufacturing process for GMR devices using a novel electrochemical delamination fabrication process. This innovative approach not only enhances efficiency but also opens new possibilities for large-scale manufacturing. Findings highlight the development of the first flexible GMR sensor array with a spin-valve structure and enhanced sensitivity to small magnetic fields. Notably, the array demonstrated long-term stability despite repeated (500) bending cycles, highlighting its potential applications in 'smart skin' and high-resolution pressure sensing.

This work represents a significant first step in achieving the goal of advanced integrated electronic skins with enhanced functionality and long service life.

Journal reference:
Hugo Francisco de Souza

Written by

Hugo Francisco de Souza

Hugo Francisco de Souza is a scientific writer based in Bangalore, Karnataka, India. His academic passions lie in biogeography, evolutionary biology, and herpetology. He is currently pursuing his Ph.D. from the Centre for Ecological Sciences, Indian Institute of Science, where he studies the origins, dispersal, and speciation of wetland-associated snakes. Hugo has received, amongst others, the DST-INSPIRE fellowship for his doctoral research and the Gold Medal from Pondicherry University for academic excellence during his Masters. His research has been published in high-impact peer-reviewed journals, including PLOS Neglected Tropical Diseases and Systematic Biology. When not working or writing, Hugo can be found consuming copious amounts of anime and manga, composing and making music with his bass guitar, shredding trails on his MTB, playing video games (he prefers the term ‘gaming’), or tinkering with all things tech.

Citations

Please use one of the following formats to cite this article in your essay, paper or report:

  • APA

    Francisco de Souza, Hugo. (2024, August 13). A revolutionary electronic skin fabrication process brings us closer to a sixth 'magnetic perception' sense. News-Medical. Retrieved on December 11, 2024 from https://www.news-medical.net/news/20240813/A-revolutionary-electronic-skin-fabrication-process-brings-us-closer-to-a-sixth-magnetic-perception-sense.aspx.

  • MLA

    Francisco de Souza, Hugo. "A revolutionary electronic skin fabrication process brings us closer to a sixth 'magnetic perception' sense". News-Medical. 11 December 2024. <https://www.news-medical.net/news/20240813/A-revolutionary-electronic-skin-fabrication-process-brings-us-closer-to-a-sixth-magnetic-perception-sense.aspx>.

  • Chicago

    Francisco de Souza, Hugo. "A revolutionary electronic skin fabrication process brings us closer to a sixth 'magnetic perception' sense". News-Medical. https://www.news-medical.net/news/20240813/A-revolutionary-electronic-skin-fabrication-process-brings-us-closer-to-a-sixth-magnetic-perception-sense.aspx. (accessed December 11, 2024).

  • Harvard

    Francisco de Souza, Hugo. 2024. A revolutionary electronic skin fabrication process brings us closer to a sixth 'magnetic perception' sense. News-Medical, viewed 11 December 2024, https://www.news-medical.net/news/20240813/A-revolutionary-electronic-skin-fabrication-process-brings-us-closer-to-a-sixth-magnetic-perception-sense.aspx.

Comments

The opinions expressed here are the views of the writer and do not necessarily reflect the views and opinions of News Medical.
Post a new comment
Post

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.

You might also like...
Scientists discover key age-related biological shifts at 40 and 60