Common ophthalmic devices measure corneal parameters using different technologies

As the recently published article in the journal Open Ophthalmology Journal shows, there are significant differences among the measures of corneal parameters obtained by the three most commonly used ophthalmic devices, called topographers.

This is a critical issue for doctors seeking to achieve the best patient outcomes for eyesight recovery after cataract surgery.

The calculation of the astigmatic power required for the intraocular lens (IOL) that is to be implanted after cataract surgery is based on the magnitude and axis of corneal astigmatism considered, which can be measured and calculated using different topographers.

The accuracy when calculating the appropriate IOL determines the quantity and quality of vision of the post-operative cataract patients and also defines their need for spectacles after the surgery.

This work, published by a team of ophthalmologists from Spain compares the measures obtained from Pentacam system (Oculus Optikgera?te GmbH, Wetzlar, Germany), Cassini (i-Optics, The Hague, The Netherlands, distributed by Ophtec) and IOL-master 700 system (Carl Zeiss Meditec AG, Jena, Germany). These three devices measure corneal parameters using different technologies.

The prospective comparative study reviews data from 94 eyes from 53 patients ranging in age from 29 to 77 years old, recruited from the anterior segment consultation at Vithas Eurocanarias Instituto Oftalmológico in Las Palmas de Gran Canaria (Spain).

Standard and total keratometric readings and astigmatism measures obtained with these devices cannot be used interchangeably, as there are statistically significant and clinically relevant differences among the results obtained."

Dr. Humberto Carreras, Study Co-Author

"Therefore, if the data of these three systems are used for toric IOL power calculations, significant differences can be expected, what will affect the post-op vision in the cataract patients?" The authors recommend that refractive predictability studies hold the answer to this question, and this needs to be investigated further for each type of optometric device.

Source:
Journal reference:

Carreras, H., et al. (2020) Comparison of Standard and Total Keratometry Astigmatism Measured with three Different Technologies. The Open Ophthalmology Journal. doi.org/10.2174/1874364102014010059.

Comments

The opinions expressed here are the views of the writer and do not necessarily reflect the views and opinions of News Medical.
Post a new comment
Post

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.

You might also like...
Weight loss drug semaglutide may offer relief for knee arthritis pain