Scientists develop color-coded X-rays to detect early disease

Medical imaging is no longer in Kansas, Toto, as a team led by Penn State researchers brings traditional black and white diagnostic images of X-rays and traditional CT scans into technicolor. The researchers developed novel contrast agents that target two proteins implicated in osteoarthritis, a degenerative joint disease commonly characterized as wear-and-tear arthritis. By marking the proteins with the contrast agents comprising newly designed metal nanoprobes, the researchers can use advanced imaging called "K-edge" imaging or photon-counting computed tomography (CT) to simultaneously track separate biological processes in color that, together, reveal more about the disease's progression than a traditional scan. 

The team published its findings in Advanced Science. The work -; done in rats but with implications for humans -; allows researchers and clinicians to see previously obscured processes in color and observe evidence of the disease long before clinical symptoms develop. 

"If we can develop a contrast agent -; a metal nanoprobe -; tailored to identify and quantify target particles, there is very little we cannot see with the photon-counting CT scanner," said first author Nivetha Gunaseelan, doctoral student in biomedical engineering at Penn State.

And that visualization is especially important when it comes to diseases such as osteoarthritis, which can progress unnoticed until clinical presentation, which is often at an advanced and irreversible stage. Early intervention could reduce symptoms and improve lifestyle, if we have the tools to enable early diagnosis and longitudinal disease tracking. We can enhance imaging techniques to detect early cartilage changes at a molecular level, and that could help improve diagnosis and monitoring."

Nivetha Gunaseelan, Doctoral Student. Biomedical Engineering, Penn State

The work hinges on a relatively new technology, the photon-counting computed tomography (CT) scanner, that reveals the same bone, muscle and fat that conventional CT scanners can detail, but has a far wider ability to separate various components at a higher resolution and in designated colors. A version of this advanced scanner, produced by Siemens, was approved by the U.S. Food and Drug Administration for clinical use and is now being placed at some hospitals, but its smaller scale, molecular imaging capabilities for clinical applications have remained largely unexplored, according to the researchers. 

The photon-counting CT scanner tracks materials with unique K-edge identities, which refers to how electrons in a material absorb energy. Electrons sit on a K-shell, a kind of casing that encompasses the nucleus of an atom. As energy is absorbed from photons, or particles of light, the electrons can jump to more external shells. The atom can absorb a certain amount of energy, and when that limit is hit, the atom will emit a flash of light. The researchers can tell the scanner to track that particular light emission, called the K-edge. If a material with a distinctive K-edge identity also targets a specific protein, the researchers can use the scanner to track that protein's activity. 

"This high-resolution, K-edge-based imaging approach could potentially be used to image multiple biological targets, thus enabling disease progression tracking over time by measuring the ratio of protein expression," said corresponding author Dipanjan Pan, the Dorothy Foehr Huck & J. Lloyd Huck Chair Professor in Nanomedicine and professor of materials science and engineering and of nuclear engineering at Penn State. "The approach can be particularly beneficial in skeletal disease diagnoses since the progression of cartilage degradation is highly variable among patients and the ratio information from the protein markers could provide crucial information about the stage of the disease." 

The researchers designed two K-edge metal nanoprobes, made of praseodymium and hafnium. The probes target two proteins in cartilage tissue: aggrecan and aggrecanase, respectively. Aggrecan, which helps provide structure and the ability to bear weight to cartilage, is abundant in healthy joints and in early stages of osteoarthritis. Aggrecanase, which cleaves aggrecan and limits cartilage's abilities, is abundant in the late stages of osteoarthritis. As the disease progresses, the ratio of the proteins shift, providing metrics to track disease status. 

The team used the photon-counting CT scanner to track how the ratio shifted as the disease progressed in an animal model. They used additional imaging and experimental validation to corroborate their results. 

"X-ray imaging has advanced greatly since Röntgen's first demonstration," Pan said, referring to Wilhelm Röntgen, the physicist who produced the first radiograph in 1895, with the hand of Anna Bertha, his wife, as the subject. "This technique has the advantage of capturing images quickly, making it a good choice for emergency situations, but it lacks soft tissue contrast and cannot separate the imaging signal from the disease site from that of intrinsic structures, such as bones." 

However, Pan explained, advanced detector technologies like photon-counting CT scanning and K-edge imaging -; which his lab has worked on for more than a decade -; have enabled highly precise and detailed imaging. 

"We are now able to count individual photons, and as a result, we can generate 'hot spot'-like images based on an element's K-edge energy," Pan said. "The results of our experiment demonstrate -; for the first time -; that a complementary biological process can be followed in multicolor, with a clinically relevant modality." 

Photon-counting CT scanning offers several clinical applications derived from such advantages as immunity to electronic noise and high-resolution imaging without compromising quantum efficiency, according to Pan. 

"We showed the potential of K-edge nanoprobes and photon-counting CT scanning in detecting critical stages of osteoarthritis before symptom development and clinical presentation with advanced stages," Pan said. "It is anticipated that the synergistic development of these tools will determine the success of this field." 

Other contributors from Penn State include members from Pan's laboratory: Pranay Saha, postdoctoral researcher in nuclear engineering; Teresa Aditya, postdoctoral researcher in nuclear engineering; and Fadia Kamal, assistant professor of orthopedics in the College of Medicine. Co-first author Parikshit Moitra, research assistant professor of nuclear engineering at Penn State during the study and current assistant professor at the Indian Institute of Science Education and Research; and Mahdieh Moghiseh, Kevin Jonker, Steven Gieseg and Anthony Butler, MARS Bioimaging Limited, New Zealand, also contributed. Pan, Gunaseelan, Moitra, Saha and Aditya are all affiliated with the Penn State Huck Institutes of Life Sciences; Pan, Gunaseelan and Moitra are also affiliated with the University of Maryland, Baltimore; Jonker and Gieseg are affiliated with the University of Canterbury, New Zealand; and Gieseg and Butler are affiliated with the University of Otago, New Zealand. 

Penn State, the Department of Defense Congressionally Directed Medical Research Programs, the Centers for Disease Control and Prevention, and the U.S. National Science Foundation partially supported this research. 

Source:
Journal reference:

Gunaseelan, N., et al. (2024) Targeted K‐Edge Nanoprobes From Praseodymium and Hafnium for Ratiometric Tracking of Dual Biomarkers using Spectral Photon Counting CT. Advanced Science. doi.org/10.1002/advs.202408408.

Comments

The opinions expressed here are the views of the writer and do not necessarily reflect the views and opinions of News Medical.
Post a new comment
Post

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.

You might also like...
Transcranial ultrasound stimulation: A new frontier in noninvasive brain therapy