The M-Series™ systems are self-shielded, high-performance MRI systems that use permanent magnet technology and do not require cryogen or cooling. The M-Series systems enable preclinical researchers, with or without extensive knowledge of MR physics, to use the gold standard method in soft tissue imaging without incurring the cost, complexity, or technical burden of superconducting MRI systems.
Mice, rats, similarly sized species/samples, and non-human primates' brains can all be imaged using varying-sized models. Permanent magnet technology eliminates additional infrastructure, reduces operating and maintenance expenses, and allows easy integration into existing lab spaces.
These 1 Tesla systems are designed for anatomical, functional, and molecular imaging applications in cancer, cardiac, neurology, and multimodal imaging. The optional SimPET insert is compatible with the M-Series and allows simultaneous PET/MRI capture.
Image Credit: Scintica Instrumentation Inc
There are no specific infrastructure needs, low operating and maintenance costs, and easy integration into existing lab space. These 1 Tesla systems are designed specifically for anatomical, functional, and molecular imaging applications in cancer, cardiac, neuroscience, and multimodal imaging.
The animal handling system uses simple, fully integrated anesthetic, warmth, and physiological monitoring devices to keep the animal stable throughout the imaging session.
Image Credit: Scintica Instrumentation Inc
The optional SimPET insert is compatible with the M-Series and allows for simultaneous PET/MRI acquisition.
MR contrast agents further enhance this imaging technique's capabilities, offering crucial information on molecular targets, myocardial infarction size, and tissue/tumor perfusion.
The M-Series product range is compatible with contrast agents based on gadolinium and iron oxide. Since they function at 1 Tesla (T), representing a greater sensitivity to the effects of gadolinium than higher-field MR systems, these systems are perfect for contrast agent imaging.
Features and benefits
The affordable and compact M-Series magnetic resonance imaging (MRI) equipment produces high-resolution 3D whole-body, anatomical, functional, and molecular images of small animals.
Self-shielded permanent magnet
Since the M-Series devices are permanent magnets, they can be placed adjacent to other furnishings or equipment in an existing laboratory or animal facility.
The citing alternatives are numerous and expenditures to change an existing space are minimal:
- No Faraday cage or additional shielding is required to protect the magnet from the environment or the environment from the magnet because the system is self-shielded.
- The system is self-shielded; therefore, no Faraday cage or additional shielding is required to protect the magnet from its surroundings or the surroundings from the magnet.
- Permanent magnets do not generate heat to create the magnetic field. Therefore, there is no liquid (helium or water) cooling and the additional equipment and space necessary for this.
- Only a single 220 V outlet is needed, and electricity is only used during imaging to power the fans, gradients, and other electronics.
The system's magnet and electronics can be positioned anywhere up to seven meters apart, giving users great flexibility.
Affordable purchase price for fully-equipped systems
MRI, the gold standard of soft tissue imaging, is now more accessible to preclinical researchers.
Fully integrated physiological monitoring, heating, and anesthesia
The coils are self-tuned and matched, and the system automatically calibrates.
The M-Series systems simplify the workflow from animal preparation to image acquisition by eliminating the need for time-consuming system calibration and set-up processes to ensure the imaging subject’s optimization with the coil and the rest of the system.
Real-time monitoring of the imaging subject ensures the animal’s stability during the imaging session.
Either the cardiac or respiratory signals can initiate image acquisition.
No electricity is required to maintain the magnetic field, so no heat dissipation (cryogens or water) is needed
The M-Series systems have low operating and maintenance expenses since they use a permanent magnet:
- Maintaining the magnetic field does not involve a steady source of electricity
- Since no heat is produced to produce the magnetic field, no extra equipment or upkeep of that equipment is needed (such as compressors and helium or water pumps)
- The M-Series has minimum maintenance requirements. The user must only attend preventative maintenance once a year; there are no daily, weekly, or monthly requirements.
User-friendly software interface with numerous sequences
Preclinical researchers without prior knowledge of MR physics can use the optimized default sequences for some of the most popular imaging applications. This enables them to obtain outstanding images of their individual animal models in a reproducible manner utilizing M-Series devices.
Minimal animal preparation steps
Animals should be minimally anesthetized as imaging subjects must remain immobile during acquisition. This can be accomplished using the integrated anesthetic system. Once ready, the imaging subject is transferred to the animal handling platform and positioned within the coil.
Standard imaging does not require any additional preparation steps, allowing for the rapid imaging of a cohort of animals without additional manipulation of the imaging subject.
Hardware and software add-ons are available to integrate other imaging modalities, such as PET and bioluminescence
Multimodal imaging combines MRI’s excellent anatomical information with the sensitivity and specificity of molecular and metabolic imaging.
Models and specifications
M3 mice only
Image Credit: Scintica Instrumentation Inc
M5 mice, rats and other small animals
Image Credit: Scintica Instrumentation Inc
M7 mice, rats and other large animals
Image Credit: Scintica Instrumentation Inc
M12 non-human primates
Image Credit: Scintica Instrumentation Inc
M-Series preclinical MRI specifications
Source: Scintica Instrumentation Inc
Specifications
Front End
(Magnet Stand) |
M3 |
M5 |
M7 |
M12 |
Dimensions
(Height x Width x Depth) |
1080 x 734 x 734 mm
42.5 x 29 x 29 inches |
1133 x 800 x 800 mm
44.6 x 31.5 x 31.5 inches |
1320 x 790 x 950 mm
52 x 31 x 37.5 inches |
1810 x 1450 x 1710 mm
71.26 x 57.09 x 67.32 inches |
Weight |
650 kg /
1430 lbs |
950 kg /
2095 lbs |
1550 Kg /
3415 lbs |
5500 kg /
12,125 lbs |
Magnet Opening
Flange Insertion
Diameter
Inner Bore (Height x Width) |
70 mm / 2.8 inches
50 x 130 mm /
2 x 5.1 inches |
No insertion flange in M5
(the bore is open)
76 x 200 mm /
3 x 7.9 inches |
97 mm / 3.8 inches
220 x 90 mm /
8.6 x 3.5 inches |
184 x 260 mm /
7.2 x 10.2 inches |
Imaging Volume |
80 x 80 x 35
mm3 spheroid |
90 x 90 x 60
mm3 spheroid |
120 x 120 x 70
mm3 spheroid |
120 x 130 x 130
mm3 ellipsoid |
Bo (Tesla) |
1T |
1T |
1T |
1T |
Back End
Electronics & Cabinet |
M3 |
M5 |
M7 |
M12 |
Dimensions |
1760 x 600 x 1150 mm
69.3 x 23.6 x 45.3 inches |
1760 x 600 x 1150 mm
69.3 x 23.6 x 45.3 inches |
1760 x 600 x 1150 mm
69.3 x 23.6 x 45.3 inches |
1760 x 600 x 1150 mm
69.3 x 23.6 x 45.3 inches |
Weight |
300 kg / 660 lbs |
300 kg / 660 lbs |
300 kg / 660 lbs |
300 kg / 660 lbs |
Gradients |
M3 |
M5 |
M7 |
M12 |
Strength |
440 (X, Y), 540 (Z) mT/m |
430 (X, Y, Z) mT/m |
150 (X, Y, Z) mT/m |
150 (X, Y, Z) mT/m |
Slew rate (T/m/s) |
1750 T/m/s |
1720 T/m/s |
500 T/m/s |
500 T/m/s |
All models
- 20-240 VAC, 15 A, single phase in countries with 220-240 V 208 VAC, 15 A, single phase in countries using 120 V
Pulse sequences
- Gradient echo with cardiac/respiratory trigger
- Gradient echo cardiac Cine
- FSE Single-shot and segmented diffusion imaging
- Diffusion-weighted imaging (DWI)
- Magnetization Prepared – Rapid Gradient Echo (MPRAGE)
- Magnetic Resonance Venography (MRV)
- Spin Echo (SE)
- Fast Spin Echo (FSE), 2D and 3D
- Gradient Echo (GRE), 2D and 3D
- Inversion Recovery modules for Gradient Echo, Spin Echo and FSE
- Dynamic Contrast Enhanced (DCE)
- FSE with Dixon water/fat separation
- FSE with cardiac/respiratory trigger
Procedures
Procedures are pulse sequences paired with specific post-processing methods.
- Water/fat separated images
- T1-mapping
- ADC (apparent diffusion coefficient) mapping
- Cardiac CINE images
Animal handling system
Fully integrated animal handling and coil system includes:
Image Credit: Scintica Instrumentation Inc
- Beds suitable for a variety of sized animals such as mice, rats, and non-human primates
- Anatomy-specific coils improve signal-to-noise ratio and image quality
- Completely integrated anesthetic delivery and gas exhaust scavenging
- Individually controlled, multi-point, isoflurane vaporizer
- Continuous monitoring of the ECG, heart rate, respiratory rate, and body temperature
- Enables ECG and/or respiratory triggering
- To keep the body temperature stable, heated water is constantly circulated
RF coils
Source: Scintica Instrumentation Inc
Type |
Inner Diameter |
Lenght |
Mouse Head |
23 mm |
25 mm |
Mouse Body |
30 mm |
50 mm |
Mouse Whole Body |
30 mm |
80 mm |
Rat Head |
35 mm |
40 mm |
Rat Body |
50/60 mm ellipsoid |
90 mm |
Large Rat Body |
71 mm |
90 mm |
Non-human Primate |
143 mm |
120 mm |
RF coils
Accessories and add-ons
The SimPET insert is a cutting-edge, small, low-power insert that fits within the M7 MRI and has exceptional PET detector stability. Based on cutting-edge silicon photomultiplier (SiPM) technology, the SimPET allows for truly simultaneous PET/MR imaging, providing high-resolution anatomical soft-tissue context and sensitive molecular and metabolic information for a variety of uses in oncology, cardiovascular biology, and neurology.
M-Series - Animal Preparation and Set up
Video Credit: Scintica Instrumentation Inc
M-Series imaging gallery
Anatomy & Morphology of mouse abdomen: T1- and T2- weighted scans of wildtype mouse body abdomen. Image Credit Scintica Instrumentation Inc
Neurobiology of mouse brain: T2- weighted images of a mouse brain. Image Credit: Scintica Instrumentation Inc
Epilepsy in the rat brain: T2- weighted images of a rat brain 48 hours after induction of epilepsy. Image Credit: Scintica Instrumentation Inc
Tumor visualization in various cancer models: Fat-suppressed T2-weighted imaging can be used to detect and quantitatively characterize the growth of a wide range of cancer models. Image Credit: Scintica Instrumentation Inc
Hindlimb tumor growth: Monitoring the growth of xenograft tumor grown in the mouse hindlimb is identified with T2-weighted images. Segmentation of tumor region of interests (in red) on each tumor-containing slice allows accurate volume quantification. Image Credit: Scintica Instrumentation Inc
Cardiac Cine loop images: Long axis view of a single slice of the heart was acquired with Cine loop images. Long-axis images can be used for strain analysis in third-party software. Image Credit: Scintica Instrumentation Inc
Ex-Vivo Imaging: Ex vivo imaging can produce high-resolution images of the rat brain, providing excellent delineation of brain regions. Image Credit: Scintica Instrumentation Inc
Multimodal Imaging: Multimodal imaging combines the strength of MRI with other imaging modalities such as PET and CT. PET provides information on the spatial distribution of molecular signal of interest. In this case MRI confirmed that the absence of tracer uptake in the center of the images was due to the presence of a necrotic core, which appears hyperintense on T2-weighted MRI. Image Credit: Scintica Instrumentation Inc
Applications
Anatomy and morphology
Numerous anatomical and morphological imaging objectives can be studied using the M-Series devices, such as:
- Metabolic conditions, such as obesity and diabetes
- Pathology of a particular organ, such as the liver, kidney, spleen, etc.
- Perfusion of tissue with a contrast agent
- Inflammation
T1- and T2- weighted images of Wild-type mouse abdomen. Image Credit: Scintica Instrumentation Inc
Maximum intensity projection show visceral fat segmentation from T1-weighted images of mouse abdomen. Image Credit: Scintica Instrumentation Inc
T2-weighted images show mouse placenta and fetal development during pregnancy. Image Credit: Scintica Instrumentation Inc
Neurobiology
The M-Series devices can be used to examine a large variety of neurological diseases and disorders, including:
- Anatomy
- Cerebral perfusion with contrast-enhanced angiography
- Targeted molecular imaging with contrast agents
- Traumatic Brain Injury (TBI)
- Inflammation
- Stroke
- Epilepsy
- Neurodegeneration
- Tumor biology
T2- weighted images of a mouse brain. Image Credit: Scintica Instrumentation Inc
T2- weighted images of a rat brain 48 hours after induction of epilepsy. Image Credit: Scintica Instrumentation Inc
T2- (top row) and T1- (bottom row) weighted images show stroke lesion and its segmentation (in red) within the rat brain. Scintica Instrumentation Inc
Cancer/oncology
The M-Series devices are suitable for studying various tumor types and disease phases. Since no alteration of tumor cells is necessary, models such as xenografts, orthotopic, transgenic, and patient-derived xenografts can be studied in a wide range of imaging subjects to focus on.
- Quantitative monitoring of tumor development
- Quantitative response evaluation for drug studies
- Tumor phenotyping, including necrosis detection
- Tumor detection
- Hypoxia and tumor hemodynamic microvasculature functional imaging (without contrast agents)
- Targeted molecular imaging with contrast agents
Fat-suppressed T2-weighted imaging can be used to detect and quantitatively characterize the growth of a wide range of cancer models. Image Credit: Scintica Instrumentation Inc
Monitoring the growth of xenograft tumor grown in the mouse hindlimb is identified with T2-weighted images. Segmentation of tumor region of interests (in red) on each tumor-containing slice allows accurate volume quantification. Image Credit: Scintica Instrumentation Inc
Monitoring tumor growth in the mouse brain, following the orthotopic injection of glioblastoma cells, using T2-weighted images. Image Credit: Scintica Instrumentation Inc
Cardiovascular biology
The M-Series systems enable cardiac images to be obtained from a wide range of imaging subjects to assess the following:
- Strain and torsion
- Myocardial perfusion
- Angiography with contrast agents
- Long and short axis acquisition
- Systolic/Diastolic Volum
- Ejection fraction
- Fractional shortening
- Wall thickness
All areas of the heart and accompanying vasculature can be easily viewed, including the left and right atrium, which would normally be difficult to image using conventional imaging modalities.
The M-Series technology significantly simplifies slice prescription for acquiring reproducible images, providing consistent data throughout a longitudinal study.
Fat-suppressed T2-weighted imaging can be used to detect and quantitatively characterize the growth of a wide range of cancer models. Image Credit: Scintica Instrumentation Inc
Short axis view of a single slice of the heart was acquired with Cine loop images. Short axis images can be used to analyze functional measurements in third-party software. Image Credit: Scintica Instrumentation Inc
Ex vivo imaging
Excised tissues preserved in formalin can undergo MRI at a resolution far higher than a live animal's. Ex-vivo 3D MRI makes identifying and measuring lesions in entire organs or brain structures possible. It can also assist in directing additional histopathological processing and sectioning for standard pathological analysis of areas of interest.
- High-resolution imaging
- Lesion detection
- Volume quantification
Ex vivo imaging can produce high-resolution images of the rat brain providing excellent delineation of brain regions. Image Credit: Scintica Instrumentation Inc
Ex vivo imaging of liver, allowing lesions to be identified, counted and measured (volume) as well as guide tissue sectioning for conventional pathological examination. Image Credit: Scintica Instrumentation Inc
Multimodal imaging
According to current preclinical imaging trends, multimodal imaging can provide synergistic information on a particular disease model or response to a target compound, and it should be considered in all studies wherever feasible. The SimPET insert can be integrated with the M-Series to enable simultaneous PET/MRI.
Alternatively, the animal can be transported to different imaging modalities using a multimodal imaging cassette to fit inside the MRI coil on the M-Series. These images can be co-registered using third-party software like VivoQuant.
Multimodal imaging combines the strength of MRI with other imaging modalities, such as PET and CT. PET provides information on the spatial distribution of molecular signal of interest. In this case MRI confirmed that the absence of tracer uptake in the center of the images was due to the presence of a necrotic core, which appears hyperintense on T2-weighted MR. Image Credit: Scintica Instrumentation Inc
MRI is a complementary method to bioluminescence imaging in the detection of tumors, allowing a more precise assessment of the location and extent of orthotopic tumors (here, an orthotopic model of prostate bone marrow metastasis). Image Credit: Scintica Instrumentation Inc
Contrast agents
Contrast agent-enabled functional and molecular imaging
The M-Series systems are ideal for T1 contrast agents like gadolinium (Gd) or manganese (Mn) because they all run at 1T. Compared to higher field strengths like 3T, 7T, or more, contrast agents offer higher signal enhancement at lower field strengths like 1T.
Furthermore, the system can be fully customized by using T2 contrast agents.
Contrast agents offer a wide range of functional and molecular imaging capabilities, including:
- Delayed contrast-enhanced imaging in the heart to examine infarct size and tissue viability in the transmural area
- Targeted molecular imaging
- Stem cell tracking
- Perfusion and vascular imaging
- Dynamic Contrast Enhanced (DCE) acquisitions
MR angiography with high T1 relaxivity liposomal-Gd contrast agents produces reconstructed 3D map of the cerebral vasculature of a mouse brain. Image Credit: Scintica Instrumentation Inc
Dynamic contrast-enhanced (DCE-) MRI shows the change in T1-signal following the remote intravenous injection of a T1 contrast agent via the lateral tail vein, which can be used to quantify vascular perfusion. Image Credit: Scintica Instrumentation Inc
Signal enhancement maps generated by subtraction of the pre-contrast T1-weighted images from post-contrast images using third-party software VivoQuant. Image Credit: Scintica Instrumentation Inc